background image

Insert pressure into cylinder (4) in order to release the brakes.

NOTE. If the machine hydraulic system cannot be used, use an

external manual pump.

Loosen and remove the external nut (7).

Release the pressure in the cylinder and disconnect the pressure

delivery tube.

Remove the fulcrum pin (3) from the cylinder (4).

Remove the snap ring (1) that checks the support (8) and remove

the distance piece (2).

Remove the cylinder assembly (4) complete with rod (5), internal

nut (6) and support (8).

Place cylinder (4) into a vice with the spring seat side (10) engaged

in it and, using a bar "D", loosen and remove the cylinder unit (9)

complete with piston (13) and spring (12).

bar

GB

GB

GB

GB

GB

GB

a

b

c

d

f

e

136

HOW TO REMOVE AND DISASSEMBLE THE EXTERNAL HYDRAULIC NEGATIVE BRAKE - RIMOZIONE E SMONTAGGIO FRENO NEGATIVO

IDRAULICO ESTERNO - AÈUûERE HYDRAULISCHE NEGATIVBREMSE ABMONTIEREN - REMOCION Y DESMONTAJE FRENO NEGATIVO

HYDRAULICO EXTERIOR - ENLEVER ET DEMONTER DU FREIN NEGATIF HYDRAULIQUE EXTERNE