12

Faults related to A10 (Parking Brake solenoid)

Any electrical fault related to the parking brake output is signalled. When such a fault is present, the
parking brake functionality is handled by the brake solenoid connected to A2-A3.

Platform drive is disabled resulting in immediate SHUTDOWN.

In Handler and Cabin Control Mode the machine is forced to stop, after which drive can be resumed
by turning off the parking.

Faults related to A20 (Parking brake lamp)

Faults related to the parking brake lamp are recognized only in following conditions:

shorts to plus are recognized when the lamp is supposed to be on

open circuit or short to ground is recognized when the lamp is supposed to be off

They are flagged but not acted upon.

2.2.9.1 Fault Codes for Discrete Output Faults

81.00

· The output is shorted to Ground

81.01

· The output is not connected or its Plus line is shorted

to Vbat

Note that the first two digits identify the output exhibiting the fault:

80

Parking brake solenoid related fault

A10

81

Forward solenoid related fault

A15

82

Reverse solenoid related fault

A16

83

Parking brake lamp related fault

A20

2.2.10 Incorrect Input Patterns

The shift lever pattern presented to the APC160 is continuously check for plausibility.

Direction selection related inputs: 40.06

A selection of Forward and Reverse at the same time immediately results in the selection of Neutral.
Neutral can be left only if a valid Neutral signal is first detected.

Range selection related inputs: 41.06

Two inputs are used to encode three ranges, allowing to do some fault checking.

An incorrect pattern is flagged as a fault. During its presence, the last correct position remains
selected.

2.2.10.1 Fault Codes for Input Pattern Faults

40.06

· Invalid shift lever direction detected

41.06

· Invalid shift lever position detected