2.2.3 Supply Voltage Out of Range

2.2.3.1 Over Voltage

The APC160 is very tolerant to large transients on its power lines. Even power supply levels up to 40 V
will not damage circuit components.

A fault indication on the display is given to warn the driver of the problem.

2.2.3.2 Under Voltage

The APC160 operates at voltages down to 9 Vdc.

Below 9 Vdc however the APC160 can enter the reset condition and shuts off all outputs.

Because the APC160's engine start disable circuit is using a normal closed relay to prevent engine
cranking in certain conditions, this is not considered as a problem.

2.2.3.3 Fault Codes for Supply Voltage Faults

30.04

· The operating voltage is too low

30.05

· The operating voltage is too high

2.2.4 Internal Faults

At power up a series of integrity checks is done.

These tests consist of the following:

· CPU integrity check (ALU, registers, operators)
· Internal RAM test (Modified March–C test)
· Program Flash memory integrity check (Modified 16 bit checksum)
· External RAM test (Modified March–C test)
· Parameter Flash memory integrity check (Modified 16 bit checksum per parameter)
· Redundant

SHUTDOWN Path integrity check

If these tests prevent operation as a transmission controller, then the APC160 locks itself in a reset
state, with all outputs off.

If faults related to shift limits are detected prohibiting safe transmission control, the APC160 reverts to
shut-down mode (SHDN). In this mode, the transmission can not be operated.

2.2.4.1 Fault Codes for Internal Faults

00.50

· There is a problem related to the Internal RAM (in CPU)

00.51

· There is a problem related to the System RAM (in CPU)

00.52

· There is a problem related to the external RAM

00.53

· There is a problem related to the FLASH program memory