9

Chapter 2 Installing and Removing the Intel®

Blade Server Ethernet Switch Module
IXM5414E

The following illustration shows the I/O module bay locations in the SB-HE platform.

Attention: To maintain proper system cooling, each I/O module bay must contain either a module
or a filler module; each blade bay must contain either a blade or a filler blade.

Ethernet interface requirements

The SB-HE platform supports a minimum of one hot-swap Ethernet switch module in I/O module
bay 1. This switch module is a fully functional four-connector Ethernet switch that provides a
network connection to Ethernet Link 1 in all the blade servers in the SB-HE. To provide a network
connection for Ethernet Link 2 in each blade server, install an Ethernet switch module in I/O module
bay 2.

If you install an interface option on any blade server, you must install a hot-swap switch module of
the same interface type in I/O module bay 3 to obtain connection 1 for the interface option. To
provide connection 2 for the interface option, install a switch module of that interface type in I/O
module bay 4. The switch modules in I/O module bays 3 and 4 provide connections to all the
interface options in the SB-HE.

Advertising