Section 10 - technical data, Technical data uk – FBT 37483_VAIE2550_manual1.pdf Manuale d'uso

Pagina 123

Advertising
background image

10-1

TECHNICAL DATA

UK

Rated output power with 230V

AC

power supply

250 W RMS – with two 250W amplifiers for a dual

voice and music channel

Rated output power with 24V

DC

power supply

160 W RMS – with two 160W amplifiers (2x220W @ 28 V

DC

)

N° of output zones

6 zones with a redundant double line (A + B)

Display

3” backlit display, 128x64 pixels

INPUTS

USB-EXT.

USB input powered via the front panel –Type A socket

Emergency microphone

• Sensitivity / Impedance

• Frequency response / S/N ratio

Balanced XLR-F on front panel

Signal level 20 mV / 10 k

60 ÷ 20.000 Hz / 72 dB

IN.1
Socket (MIC.)

• Sensitivity / Impedance

• Frequency response / S/N ratio

Programmable modes: ON / OFF / Precedence / Mix con IN.2
Balanced XLR-F (with activatable 21 V phantom power supply)

Signal level Min. 3 mV - Max 100 mV / 1.8 k

240 ÷ 20.000 Hz / 63 dB

IN.2

Socket (MIC.)

• Sensitivity / Impedance

• Frequency response / S/N ratio

Socket (LINE)

• Sensitivity / Impedance

• Frequency response / S/N ratio

Programmable modes: ON/ OFF / Precedence / VOX con A.P.T.

Balanced XLR-F (with activatable 21 V phantom power supply)

Signal level Min. 3 mV - Max 100 mV / 1,8 k

240 ÷ 20.000 Hz / 63 dB

Balanced with terminals (HOT-COM-GND)

Signal level Max 1800 mV / 31 k

60 ÷ 20.000 Hz / 84 dB

IN.3
Socket (LINE-VOX)

• Sensitivity / Impedance

• Frequency response / S/N ratio

Programmable modes: ON/ OFF / VOX con A.P.T.

Balanced with terminals (HOT-COM-GND)

Signal level Max 3600 mV / 3 k

90 ÷ 20.000 Hz / 86 dB

AUX

• Sensitivity / Impedance

• Frequency response / S/N ratio

RCA stereo socket for source of sound (BGM) - Conversion to mono

Signal level Max 1800 mV / 31 k

60 ÷ 20.000 Hz / 84 dB

Paging units

• Sensitivity / Impedance

• Frequency response / S/N ratio

2 RJ45 sockets per unit (PA) - MBT 1106 / MBT 1112
Signal level Max 1400 mV / 85 k

60 ÷ 20.000 Hz / 83 dB

EMERGENCY UNITS

RJ45 for connection and dedicated emergency microphone station.

EXT. AMP.IN

External amplifier input with terminals 0 - 70 - 100V (max. 250W RMS).

OUTPUTS

Constant voltage outputs

• Load impedance (VAIE 2250 only)

• Load impedance (with 250 W external amplifier)

6 zones for dual-line /A/B) 100 V lines - Tot. 12 pairs of terminals, 2.5 mm

2

Min. 40

 for total group of zones 1 to 6

Min. 40

 for total group of zones 1 to 3 / Min. 40 for total group of zones 4 to 6

External amplifier

• Sensitivity / Impedance

• Frequency response / S/N ratio

Output for external amplifier with balanced XLR-M socket and level 0 dBV

1 V / 500

Ω

40 ÷ 20.000 Hz / 84 dB

Monitor BF OUT

• Output / Impedance

Loudspeaker built into front panel 1 W / 8

Rear output with terminals (HOT-GND) - 1 V / 400

CONNECTIONS TO EXTERNAL PERIPHERAL UNITS

Remote links

• Sensitivity / Impedance of

voice – music channels

• Output / Impedance of

voice – music channels

RJ45 for connection to secondary VAIE 2250 unit (slave).

Signal level Max 3600 mV / 3 k

1 V / 400

Emergency controls

• CONTROL INPUTS

• CONTROL OUTPUTS

Programmable to

normally open or normally closed states.

8 inputs with diagnostics. Terminals and service power supply: 24 V

DC

6 open-drain outputs, max 200mA. Terminals and service power supply: 24 V

DC

2 relays for signalling emergencies and failures, N.O-N.C. terminals - Exchange

Precedence IN 1 - IN 2

Precedence input and terminals with common +12 VDC power supply.

LAN

LAN RJ45 socket for TCP/IP connection to web server.

GENERAL INFORMATION

230V

CA

power supply

Max consumption @ rated output power RMS
Typical consumption with voice signal
Consumption with no signal (test tone only)

230 V

CA

50/60 Hz

(500W System) P = 650W/800VA - (250W System) P = 370W/480VA
(500W System) P = 160W/200VA - (250W System) P = 90W/120VA
P = 30W/45VA

24V

DC

secondary power supply

Max consumption @24V

DC

(@28V

DC

)

Typical consumption with voice signal @24V

DC

(@28V

DC

)

Consumption with no signal (test tone only)

24 VCC (min 22Vcc ÷ max 28Vcc)
500W System =17A (21A) - 250W System =9A (11A)
500W System =4,3A (5A) - 250W System = 2,2A (2,5A)
0,8A

Operating environmental conditions

Temperature: +5°C to +40°C Relative humidity: 25%-75% non-condensing

Mounting

Optional AC8506 brackets for mounting in 19” rack (height: 3U + 1U support brackets).

Size (W x H x D) / Size, packaged (W x H x D)

439 x 387 x 132 mm / 535 x 470 x 225 mm

Net weight / Gross weight

20,5 kg / 22 kg

Advertising