USING THE SYSTEM

UK

8.5.1.5 AMPLIFIER

FAULTS

Power amplifier diagnostics and GND fault

From the FAULTS panel (point 8.5.1), press numerical key 3 and
access the panel for viewing the power amplifier diagnostics and
ground faults of the loudspeaker lines.
The diagnostic state of each item monitored is reported, as
shown in the following table.

Press ESC to return to the panel FAULTS.

Label

Part being diagnosed

Display

Cause

Action required

All

All

OK

No failures

-

N.T.

NOT TEST. Diagnostics disabled

during configuration (See Set>

BACKGROUND TEST menu)

-

Res.

Failure cleared due to previous

Fault signal

Access the Report> FAULTS panel from the

OPERATOR menu and carry out a MANUAL

RESET of the FAILURE signal.

Voice amp.

Internal amplifier of

voice

channel

Fault

Current failure due to

critical path

Contact Servicing.

Music amp.

Internal amplifier of

music

channel

Contact Servicing.

Est. amp.

External amplifier for

power expansion

Check the cables connecting the amplifier

to the EXT.AMP IN / EXT. AMP OUT sockets

and operation of the external amplifier.

Gnd Fault

Ground Fault

Dispersion to earth from at least

one speaker line

Disconnect one speaker line at a time to

identify the failed line.

Restore line insulation.

Reconnect the speaker line and carry out a

MANUAL RESET of the FAILURE signal by

accessing the Report> FAULTS panel from

the OPERATOR menu.