Campomatic C46VM Manuale d'uso

Pagina 36

Advertising
background image




SAFETY AND CHECKING SYSTEMS

• Clixon (thermal protection pad) mounted on the pump motor which intervenes if there is
overloading or a fault. The pad intervenes when a motor temperature of 150°C (class F) is
reached.
• Voltage card with redundant safety circuit for soldering.
• Pressure check in the vacuum-chamber operated by the circuit board using a pressure sensor.




TECHNICAL CHARACTERISTICS

Tension:

230V/50Hz

Maximum input power:

150W

Vacuum pump motor power:

120W/50Hz – 150W/60Hz

Vacuum pump nominal rate:

4m³/h

Empty level:

4 (preservation, cooking, jars, large vacuum-

sealing jars)

Theoretical end pressure (absolute):

2-5 millibar (cooking cycle / MAX)

Vacuum pump oil type:

SW40 (specific for vacuum pumps)

Load vacuum pump oil:

0.06 dm³

Vacuum-chamber volume:

around 17.10 litres

Effective soldering length:

300mm

Maximum bag format:

Width 300mm x length 400mm

Vacuum-pack container capacity:

Vacuum-pack box Ø270 x H135mm; “Bormioli”

Jar 1lt

Net

weight:

46 kg

Drawer stroke in working phase:

505 mm

Vacuum-chamber basin size:

355 mm width x 365 length x 187 depth

 
 

36

Advertising