If this type of signal should appear, turn the machine off and wait around 15 minutes for it to cool
down and for the thermal protection to be automatically restored.
Switch the machine back on. If the fault signal is shown, remove the power lead from the plug and
call the Retailer or authorised service centre informing them about:
 

The matriculation plate data (the plate is positioned on the underside of the drawer).

The purchase date.

 

Caution! Do not try to repair or adjust the device in any of its parts, it could be dangerous
and affect the guarantee; only authorised and qualified technicians should be entrusted to
do so.

Insufficient vacuum signal
 
The SV46 is equipped with a mechanism which reveals the level of vacuum reached inside the
chamber and which is decisive to the correct working of the device. If the minimum level of vacuum
(350 millibar pressure inside the chamber) is not reached after around 1 minute, the cycle is

automatically interrupted. The device signals the fault with the

button lighting, which

blinks for around 20 seconds, accompanied by an intermittent acoustic signal.
The signal stops when a new cycle is activated. If the cause is not removed, the above described
alarm situation is repeated.

If the insufficient vacuum signal should occur, before calling the Retailer or authorised assistance
centre, check that the lid is properly closed and the seal is properly inserted.

If, after having undertaken these checks, the fault persists, call the Retailer or authorised
assistance centre communicating the matriculation plate data.

Caution! Do not try to repair or adjust the device in any of its parts, it could be dangerous
and affect the guarantee; only authorised and qualified technicians should be entrusted to
do so.


Temporary interruption of the electricity supply

If, during a working cycle, the electricity supply is interrupted, when it is restored the vacuum
chamber is decompressed and the machine returns to the initial switching-on state.

Wait around 20 seconds before starting-up a new cycle.

If the electricity supply is interrupted in the initial start-up phase, the machine returns to the initial
switching-on state when power is restored.