Application example
Switch-on point = 2000 W, switch-off point = 1800 W

If the inverter is outputting 2000 W or above, then the floating switch contact on the inverter
is switched on.
If the inverter output falls to below 1800 W, the floating switch contact is switched off.

Possible applications:
operating a heat pump or an air-conditioning system using as much self-generated power
as possible

Time / date

Set the time, date and automatic changeover between summer and winter time

Set time
Set the time (hh:mm:ss or hh:mm am/pm - depending on the setting in the time display for-
mat)

Set date
Set the date (dd.mm.yyyy or mm/dd/yyyy - depending on the setting in the date display for-
mat)

Summer/winter time
Activate / deactivate automatic changeover between summer and winter time

IMPORTANT! The correct time and date is a prerequisite for the correct display of day and
year values and the day characteristic.

Setting range

Set time / set date / time display format / date display format /
summer/winter time

Time display format
for specifying the time display format

Setting range

12hrs / 24hrs

Factory setting

Depends on country setup

Date display format
for specifying the date display format

Setting range

mm/dd/yyyy / dd.mm.yy

Factory setting

Depends on country setup

NOTE! Only use the automatic summer/winter time changeover function if the
Fronius Solar Net ring does not include any LAN- or WLAN-compatible system
components (e.g. Fronius Datalogger Web, Fronius Datamanager or Fronius Hy-
bridmanager).
If it does include such system components, then this function should be switched
on using the system component's web interface.

Setting range

on / off

Factory setting

on