Fronius Symo x.x-3-S Manuale d'uso

Pagina 36

Advertising
background image

34

Display settings

Language
Set language for display

Night mode
DATCOM night mode; controls the DATCOM and display operation during the night or
when the DC voltage is insufficient

Contrast
Set the contrast on the display

Since the contrast is temperature-dependent, when the ambient conditions change it may
be necessary to adjust the 'Contrast' menu item.

Illumination
Initial setting for display illumination

The 'Illumination' menu item only relates to the display backlighting.

Setting range

Language / Night mode / Contrast / Lighting

Setting range

German, English, French, Dutch, Italian, Spanish, Czech, Slo-
vak, etc.

Setting range

AUTO / ON / OFF

Factory setting

OFF

AUTO:

DATCOM mode is always in effect as long as there is a Datalogger connect-
ed in an active and uninterrupted Fronius Solar Net.
The display remains dark during the night, but can be activated by pressing
any key.

ON:

DATCOM mode is always in effect. The inverter supplies 12 V continuously
to power the Fronius Solar Net. The display is always active.

IMPORTANT! If DATCOM night mode is set to ON or AUTO when there are
Fronius Solar Net components connected, then the inverter's current con-
sumption during the night will increase to around 7 W.

OFF:

DATCOM will not run at night, the inverter will not need any AC current in
order to supply power to the Fronius Solar Net.
The display is switched off during the night and the Fronius Datamanager is
not available.

Setting range

0 - 10

Factory setting

5

Setting range

AUTO / ON / OFF

Factory setting

AUTO

AUTO:

Display backlighting is activated by pressing any key. If no key is pressed for
2 minutes, the display backlighting will go off again.

ON:

The display backlighting remains permanently on when the inverter is
switched on.

OFF:

The display backlighting is permanently switched off.

Advertising
Questo manuale è associato alle seguenti prodotti: