Menu items in the Set-up menu

Standby

Manual activation / deactivation of Standby mode

-

No energy is fed into the grid.

-

The Startup LED will show steady orange.

-

In Standby mode, no other menu item at menu level can be accessed or adjusted.

-

The automatic switchover into the 'NOW' display mode after 2 minutes of keyboard in-
activity does not occur.

-

Standby mode can only be terminated manually by pressing the 'Enter' key.

-

Feeding energy into the grid can be resumed at any time (deactivate 'Standby').

Switching off Standby mode (manually switching off feeding energy into the grid):

Select the 'Standby' item
Press the 'Enter' key

'STANDBY' and 'ENTER' appear alternately on the display.
Standby mode is now active.
The Startup LED shows steady orange.

Resuming feeding energy into the grid:

'STANDBY' and 'ENTER' appear alternately on the display when in Standby mode.

Press the 'Enter' key to resume feeding energy into the grid

The 'Standby' menu item is displayed.
At the same time, the inverter enters the startup phase.
The operating state LED shows steady green when feeding energy into the grid has been
resumed.

DATCOM

Checking data communications, entering the inverter number, DATCOM night mode, pro-
tocol settings

Status
Indicates data communication is taking place via a Fronius Solar Net or that a data com-
munications error has occurred

Inverter number
Sets the number (= address) of the inverter in a system with several solar inverters

1

2

1

Setting range

Status / inverter number / protocol type

Setting range

00 - 99 (00 = 100th inverter)

Factory setting

01

IMPORTANT! If a number of inverters are linked together in a data communications sys-
tem, assign a unique address to each one.