MNVADCJ01_0543

6.6.10 Auto scan c ontrol

6.6.10.1 Control

Normal

Alarm

7&!

:

7&"

:

start

stop

7&#

:

7&$

:

start

stop

6.6.10.2 Preset posit ions

7!***

: add all preset positions

7!*55

(1÷99): add a single preset position

7!!**

: remove all preset positions

7!!55

(1÷99): remove a single preset position

7!"55

(1÷99): dwell time in seconds after reaching a position

7!#**

: request a maximum speed movement

7!#*5

(1÷8): set a reduced speed factor

6.6.10.3 Alarm positi ons

7"***

: add all alarm positions

7"*55

(1÷99): add a single alarm position

7"!**

: remove all alarm positions

7"!55

(1÷99): remove a single alarm position

7""55

(1÷99): dwell time in seconds after reaching a position

7"#**

: request a maximum speed movement

7"#*5

(1÷8): set a reduced speed factor

6.6.11 Timers

7$*55

(00÷56): autopan stop

00: continuous; 01÷23: from 5 to 115 minuts (step 5 minutes); 24÷44: from 2 to 12 ore (step 30 minuts); 45÷56:
from 13 to 24 hours (step 1 hour)

7$555

(1ч8, 00ч28): aux contacts reset.

The first X cypher is the number of Aux contact (1÷8); the following ones the time:
00: continuous; 01÷05: from 1 to 5 minuts (step 1 minute); 06÷15: from 10 to 55 minuts (step 5 minuts); 16÷27:
from 1 to 12 hours (step 1 hour); 28: 24 hours

7$)55

(00÷28): wiper stop*

7%*55

(00÷28): washer stop*

7%!55

(00÷28): light stop*

7%"55

(00÷28): heater stop*

7%#55

(00÷28): fan stop*