ATTENTION

The LPG cylinder in the compartment below the barbecue unit, must be isolated from it by a
non-combustible panel. The compartment must comply with the requirements of EN 498.

The ventilation requirements of EN 498 for the cylinder compartment are:

In case of a sheet metal, or similar impenetrable, structure, ventilation openings must be
made on the top and bottom the compartment or cavity, each of which must provide a free
surface of at least 200 cm2 per cylinder housed; the openings also serve as inspection
points if a rubber hose is used.

lunghezza max 1,5 metri

min 20 mm

distanza minima dalla parete 55mm

30

210

minimum distance from the rear wall 55mm

max length 1.5 metres