External surface area example 4

open side for at least 25% of the
total area of the walls

in total 30% or more of the remai-
ning surface of the walls is open
and free

External surface area example 5

open side for at least 25% of the
total area of the walls

in total 30% or more of the remai-
ning surface of the walls is open
and free

Selection of the point of installation

The appliance must not be installed on combustible materials. The minimum distance from
combustible materials is 600 mm.

The free space above the cooking surface with respect to combustible materials must be at
least 600 mm.

The appliance must be installed in accordance with standards and local deviations.

When using LPG, ventilation must be ensured in the compartment. The gas is highly
explosive and can cause serious personal injury and property damage if it is left to
accumulate and then ignited.

The barbecue is designed to be mounted in a counter with a minimum depth of 600 mm.

Avoid locations exposed to the wind as this may affect cooking and the efficiency of the
burners. If you cannot avoid such a location, screens may be necessary.

Installation compartment

The barbecue requires a non-combustible barrier beneath it to prevent reaching an
excessive temperature in compliance with the current UNI EN 498 standard. The panel that
acts as a barrier must be positioned 30 mm below the base of the unit.

The installation compartment must be made of non-combustible materials. Materials suitable
for its construction include brick, granite, marble, Hardiplank® and Villaboard® on a metal or
brick structure.