Fulgor Milano SBQ 1000 G Manuale d'uso

Pagina 71

Advertising
background image

70

71

GB

Gas connection

Connect the appliance to the cylinder or system according to the requirements of current law,
making sure that the appliance is configured for the type of gas available. If not, see: “Adapting
to different types of gas”. Also check that the feed pressure falls within the values shown in the
table: “Gas specifications”.

Rigid and semi-rigid metal and rubber hose connection

Make the hook-up with metal fittings and pipes (even flexible hoses) so as not to stress the
components inside the appliance.
A rubber hose connection complies with current law only if the hose can be inspected along its
entire length and easily replaced near the expiration indicated on the hose.
NOTE: - After installation, use soapy water to check the perfect seal of the entire connection
system. DO NOT USE AN OPEN FLAME TO CHECK THE GAS SEAL.

Advertising