14 panasoni c dome – Videotec DCJ Manuale d'uso

Pagina 227

Advertising
background image

Page 95

MNVADCJ01_0543

6.14 Panasoni c Dome

6.14.1 Reference m aterial and documents

Dome Panasonic WV-CS600 e Panasonic WV-CS850
Protocol Information WV-CS850 ver 2.2, Nov.28, 2001
Protocol Information WV-CSR600, WV-CSR400, WV-BSR300 ver 5.3, Nov.27, 1997

6.14.2 Important p rotocol note

The Panasonic protocols allow the control of a range of domes with different features. As the protocols have
been wholly implemented the following commands can be used both for the WV-CS600 and WV-CS850 models
or they’re peculiar of only one model. Where possible, this difference has been specified in the following
paragraphs. In any case, check in the dome instruction manual for the available functions list.

6.14.3 Connection

6.14.3.1 Cable

White

Yellow

RS485A

RS485B

Yellow

Green

Panasonic WV-CS600

Panasonic WV-CS850

6.14.3.2 Dome settin gs

Warning! Even though the two Panasonic dome control protocols (Panas600 and Panas850) are compatible to
a certain degree, to achieve better control of the dome we advise choosing the more suitable.

Set “Conventional protocol”, LOCAL (not REMOTE)

8 data bits, no parity, 1 stop bit, Full Duplex

Wait time = 0

Dome ID-number must be set according to the respective installation manual.

Baudrate can be selected among the following values: 2400, 4800, 9600, 19200 (default) baud.

6.14.3.3 Keyboard se ttings

During Keyboard setup, submenu

RRQRO

must be suitably set:

PROP

5272*2UD(1(6"

211,*7PD,UPO

(8+5(7,DC%

Panasonic 600

Baudrate must be equal to the one selected for the dome.

PROP

5272*2UD(1(6$!

211,*7PD,UPO

(8+5(7,DC%

Panasonic 850

Baudrate must be equal to the one selected for the dome.

Advertising