Page 66

MNVADCJ01_0543

6.5 BOSCH B asic Dome Series Dome

6.5.1 Materials a nd reference documents

Dome: BOSCH Basic Dome Series.
Basic Dome Series instruction manual.
Autodome R/D Robin Hood PLUS , Product version 5.00, Rev.10/04/2004

6.5.2 Connection

6.5.2.1 Cable

The Basic Dome series has two communication modes: RS232 and Bi-phase.
The DCJ console, on the other hand, communicates in RS485 mode. This is why piloting BOSCH systems
requires additional protocol converters.
For further details see the example in the illustration.

DCJ

RJjack 1

RS485A

white

RS485B

yellow

NOTE: in the case of communication using RS232 mode, a level converter is needed for each dome.

DCJ

RJjack 1

RS485A

white

RS485B

yellow

Connection with the dome in RS232 communication mode

Connection with the dome in BIPHASE communication mode

To other Devices

RS485

RS485

RS232

RS232

RS232

RS485

Level Converter

RS485

RS485

RS485

RS232

RS232

Level Converter

BOSCH

RS232 to BIPHASE
Protocol Converter

Model: LTC8786

1

2

3

4

5

6

7

8

9

Rx

GND

Advertising