MNVADCJ01_0543

7"**%

, remove position 5

7#**%

, 5 seconds dwell time between one position and the next



, start the patrol sequence.

6.9.6 Auxiliary re lays

- 5

(1÷8): activate relay X

. 5

(1÷8): deactivate relay X.

6.9.7 Lenses

: autofocus on



: autoiris on

6.9.8 Return pos ition

It is possible to configure the dome to move automatically to a “return position” after a set interval of inactivity.

7$555

, where X consists of:

the first two digits show the return position to be considered (only positions from 1 to 99 are allowed;
positions from 100 to 128 can not be selected)

the third digit shows the return time:

0: 10 seconds,

1: 20 seconds,

2: 30 seconds,

3: 40 seconds,

4: 1 minute,

5: 2 minutes,

6: 5 minutes,

7: 10 minutes,

8: 20 minutes,

9: 40 minutes

For example, the code

7$"!&

sets the dome to return to position 21 after 5 minutes of

inactivity.

6.9.9 Other spec ial codes