List of faults – FBT VAIS-1000.2 Manuale d'uso
Pagina 43

41
List of faults
Wrong date
Temp. sensor
24V fuse
Spare amplif.
VAIS XX
Wrong date
Temperature sensor failure
24V supply fuse damaged
Backup amplifier damaged
Fault at XX module
Restore date
Contact the service centre
Replace fuse F9
Fuse F2 or contact the service centre
Fault at XX module
Displace jumper J34
Check the connection cable for damage
Check the connection cable for damage
Check the connection cable for damage
Check the connection cable for damage
Contact the service centre
Check the cable for damage + check fuse F3 - see page 30
Contact the service centre
Fuse F4 or contact the service centre
Fuse F1 or contact the service centre
Contact the service centre
Contact the service centre
Check the cable
Check the cable
Autoreset disab.
Alarm cable Ex
Alarm cable Ex2
Alarm cable
Alarm cable 2
Alarm relay
Alrm rly cable
ADC converter
Amplif. 1
Amplif. 2
Alert message
Audio path
Audio cable
Audio cable 2
Jumper autoreset disabled
Interruption of alarm command cable towards the extension module
Interruption of alarm2 command cable towards the extension module
Module alarm command cable-master module interrupted
Module alarm2 command cable-master module interrupted
Alarm contact relay damaged
Alarm output cable damaged, end line resistance absent
Measurement circuit failure
Amplifier 1 damaged
Amplifier 2 damaged
Alert message corrupted
Damage of internal electronic circuit
Audio cable for transmission between Master/Slave/Extens. module interrupted
Audio cable 2 for transmission between Master/Slave/Extens. module interrupted
TEXT
TYPE
ACTION
Contact the service centre
No action
Replace battery
Replace fuse F7
Contact the service centre
Contact the service centre
Contact the service centre
Contact the service centre
Restart module (INT1)
Restart module (INT1)
Contact the service centre
Contact the service centre
No action
Replace battery
Broken clock
Battery low
Btr sischarged
Btr capacity
Btr broken
Batt chgr fuse
Batt. charger
Circ. mis. A
Circ. mis. B
Config. file
COM1 thread
COM2 thread
COM1 broken
COM2 broken
Broken clock
Low battery voltage
Battery is down
Battery charger fuse
Failure of battery charger
Line A measurement circuit damaged
Line B measurement circuit damaged
Machine configuration file corrupted
Serial port 1 management program blocked
Serial port 2 management program blocked
COM1 serial port damaged
COM2 serial port damaged
Exhaust battery
Battery failure
Check the cable for damage + check fuse F9
Check the cable for damage + check fuse F9
Contact the service centre
Check the cable for damage + check fuse F3 - see page 30
Contact the service centre
Contact the service centre
Displace jumper J1
Restart system (INT1)
Unlock the button
Contact the service centre
Restart module (INT1)
Contact the service centre
Contact the service centre
Contact the service centre
Replace fuse F8
Check the cable
Check the cable
Replace firemic
Replace firemic
Contact the service centre
Replace firemic
Check the cable
Check the cable
Contact the service centre
Glb alert cable
Glb emer cable
Fault relay
Fault rly cable
Emergency key
Ext supervisor
Jumper J1
Int. power
Keybord thread
Key lock
Flash disk
Fault thread
Emergecy msg
Flash: Eboot
Flash: code
Fuse desk
Firemic cable
Firemic cable 2
Firemic switch
Firemic coil
Firemic preamp
Fmic switch lck
Data1 VAIS XX
Data2 VAIS XX
Global alert contact cable interrupted
Global emergency contact cable interrupted
Fault contact relay damaged
Fault contact cable interrupted, end line resistance absent
Emergency key circuit (failure at level 2)
Module automatic reset circuit failure
Diagnostics jumper undergoing test
Button management program blocked
Locked button
Damage occurred in the flash disk that contains messages
Fault checking program blocked
Emergency message corrupted
Damage occurred in the flash memory that contains the startup code
Damage occurred in the flash memory that contains the program
Fuse for external consoles supplying
Audio cable for firemic transmission between Master and Slave module interrupted
Audio cable 2 for firemic transmission between Master and Slave module interrupted
Firemic switch failure
Firemic coil failure
Firemic pre-amplifier failure
Firemic switch blocked in ON position
Interruption between data cable 1 and module XX
Interruption between data cable 2 and module XX
Damage of internal circuit
Check the cable for damage + check fuse F9
Check the cable for damage + check fuse F9
Check loudspeaker lines
Check loudspeaker lines
Line not connected
Line not connected
Check loudspeaker lines
Check loudspeaker lines
Check loudspeaker lines
Check loudspeaker lines
Contact the service centre
Contact the service centre
Loc alert cable
Loc emer cable
Line A GND
Line B GND
Line A open
Line B open
Line A short
Line B short
Line A Imp
Line B Imp
Language
Log disk
Local alert contact cable interrupted
Local emergency contact cable interrupted
Line A of loudspeakers short to ground
Line B of loudspeakers short to ground
Line A of loudspeakers open
Line B of loudspeakers open
Short circuit at Line A of loudspeakers
Short circuit at Line B of loudspeakers
Line A of loudspeakers interrupted
Line B of loudspeakers interrupted
Language file corrupted
Damage occurred in the flash disk that contains the message logs
Contact the service centre
No action
Contact the service centre
Failure of power supply or fuse F10
Connect the battery + fuse F5
Contact the service centre
Contact the service centre
Main Mixer
Rebooted module
Pen drive pwr
Main power
No battery
Pwr amp relay
MSG generator
Mixer circuit failure
Module in automatic restart
USB port control circuit failure
Primary power supply absent
Battery absent
Power supply switching circuit for final amplifiers
Message generator failure