O

PERATING

M

ANUAL

1-B

YTE

M

EMORY

C

HANNEL

N

UMBER

D

ATA

S

TRUCTURE

This identifies the current or last-selected memory

channel 1 ~ 99, P1 ~ P5 or QMB 1 ~ 5 for operation.
The table below translates hexadecimal codes into
corresponding memory channel numbers. Please read
the note in the box at the page bottom.

S

ELECTING

U

PDATE

D

ATA

TO

D

OWNLOAD

As mentioned before, there are four opcodes that

cause the MARK-V FT-1000MP

Field to report (update)

its operating status by downloading all or a portion of
its 1,863 data bytes. These opcodes are shaded in the
CAT Commands table (pages 94 ~ 97).

Status Update (Opcode 10H) - The 1st and 4th

parameters of this command allow selecting different
portions of Status data to be returned, as follows (“X”
is the 1st parameter, “U” is the 4th):

Read Flags (Opcode FAH) -This command can be

set to retrieve all six Status Flag bytes, or else five bytes
- three Status Flag Bytes, plus two transceiver ID bytes.
The Status Flag Bytes are described on the preceding
page, and in the Record Tables on the previous page.

The transceiver ID bytes are used in programs to

distinguish the MARK-V FT-1000MP

Field from other

models, which have different, unique values returned
in this situation. The constant values of 03H and 93H
are returned by the MARK-V FT-1000MP

Field (and

only the MARK-V FT-1000MP

Field), as shown:

Read Meter Data (Opcode F7H) - Sending this com-

mand returns a digitized meter deflection indication,
between 00 and FFH (usually around F0H maximum).
Four copies of this value are returned, along with one
padding byte (F7H), as follows:

During reception, the signal strength deflection is

returned. During transmission, the parameter repre-
sented by the reading returned depends on the setting
of the METER switch.

CAT System Computer Control

Important Note!

The Hex Memory Channel Codes for returned
memory data shown above (Byte 7) are different
than those used in upload command data
(opcodes)!

The memory channel hex codes used as argument
(parameter) bytes for opcodes are offset by one
(that is, one value greater) from their returned data
counterparts. Therefore the channel hex codes
used in opcodes 02H, 03H, and 0DH would range
from 01H ~ 71H.

When constructing command block bytes, ensure
that the correct memory channel hex code is used!

Ch.

91
92
93
94
95
96
97
98
99

P1
P2
P3
P4
P5
P6
P7
P8
P9

Q1
Q2
Q3
Q4
Q5

Ch.

01
02
03
04
05
06
07
08
09
10

11

12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

Hex
00H
01H
02H
03H
04H
05H
06H
07H
08H
09H

0AH
0BH

0CH
0DH

0EH
0FH

10H

11H

12H
13H
14H
15H
16H
17H
18H
19H

1AH
1BH

1CH
1DH

Ch.

31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60

Hex

1EH

1FH

20H
21H
22H
23H
24H
25H
26H
27H
28H
29H

2AH
2BH
2CH
2DH
2EH

2FH

30H
31H
32H
33H
34H
35H
36H
37H
38H
39H

3AH
3BH

Ch.

61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90

Hex

3CH
3DH

3EH

3FH
40H
41H
42H
43H
44H
45H
46H
47H
48H
49H

4AH
4BH

4CH
4DH

4EH

4FH
50H
51H
52H
53H
54H
55H
56H
57H
58H
59H

Hex

5AH
5BH
5CH
5DH
5EH

5FH

60H
61H
62H
63H
64H
65H
66H
67H
68H
69H

6AH
6BH
6CH
6DH
6EH

6FH

70H

Memory Channel Data (Hex Codes)

Meter

Meter

Meter

Meter

F7H

Byte

Byte

Byte

Byte

Flag Byte Flag Byte Flag Byte ID Byte 1 ID Byte 2

1

2

3

(03H)

(93H)

Advertising