0-8 Auto-uP

Auto Channel Up - When programming memo-

ries from the VFO, this feature automatically increments
selection to the next higher memory channel. This al-
lows programming sequential memories more easily
(you don’t have to manually select the next memory to
be written). This also prevents inadvertently overwrit-
ing stored memories.

0-9 EdSP

EDSP on/off - Enables/Disables the EDSP feature.

This parameter should always be set to “On” unless
you have a compelling reason not to use the EDSP
system.

1-0 diAL-SPd

VFO A & B Dial FAST Tuning Rate - Selects x2 or

x4 tuning when the [FAST] button is pressed.

1-1 SJ-SPEEd

Shuttle Jog Encoder Speed - Selects the encoder

pulse duration from 1 ~ 100 msec (in 1 msec steps).

1-2 SFt-StEP

IF SHIFT/WIDTH Control Tuning Step Size - Se-

lects 10 or 20-Hz step size. Total knob tuning range is
62 encoder steps (with 20-Hz step size the shift range
is double that with 10-Hz).

1-3 A-StEP

MAIN VFO-A Tuning Step Size - Selects 0.625 Hz,

1.25 Hz, 2.5 Hz, 5 Hz, 10 Hz, or 20 Hz tuning steps.

1-4 b-StEP

SUB VFO-B Tuning Step Size - Selects 0.625 Hz,

1.25 Hz, 2.5 Hz, 5 Hz, 10 Hz, or 20 Hz tuning steps.

1-5 cH-StEP

VFO Channel Step Size - For the Channel Step-

ping feature, step size can be selected from 1 ~100
kHz (in 1-kHz increments).

1-6 q-SPLit

Quick Split Offset Tuning - Select a tuning offset

of up to ±100 kHz (in 1-kHz steps). See menu selection
8-2
: Split mode, A=B.

1-7 AutoFASt

Automatic Selecting of AGC recovery time -

When the front panel AGC selector is set to the “AUTO”
position and this feature is “ON,” the AGC decay time
automatically is set to “FAST” during the following op-
erating situations:

¦ During scanning;
¦ In 250/500 Hz bandwidth; and
¦ When you turn the VFO Knob for more than ½-

second.

1-8 cLAr-tun

Clarifier Tuning Offset - Enables/disables the off-

set tuning meter above the Main VFO frequency dis-
play. As the [CLAR] control is rotated and the TX or RX
frequency is offset, a single meter segment shifts to
show your relative offset from the original frequency.

1-9 cLAr-StP

Clarifier Tuning Step Size - Selects 0.625 Hz, 1.25

Hz, 2.5 Hz, 5 Hz, 10 Hz, or 20 Hz tuning steps used
with the RX and TX CLAR control.

2-0 Scn-PAuS

Scan Pause - Enables/disables pausing on activity

while scanning.

2-1 Scn rES

Scan Resume Mode - Selects one of three scan-

stop modes:

Carrier Stop - Scanning pauses on activity, resumes
when signal disappears.

Carrier Timed Stop - Scanning pauses on activity
for 5 seconds then resumes scanning for the next
station (whether signal remains or not).

Carrier Timed Slow - Scanning slows down for 5
seconds after detecting activity, then resumes to
normal scan rate.

2-2 (Not Used)
2-3 nScn-SPd

Memory Scan Speed - This sets the scan dwell

time, which is the time duration that the scanner
samples each memory channel. This duration can be
set from 100 ~ 1000 msec, in 10 msec steps.

2-4 dScn-SPd

Dial (VFO) Scan Speed - This sets the dwell time

that the scanner samples each VFO channel. This
duration can be set from 1 ~ 100 msec, in 1 msec
steps.