CHAMBER PROBE MALFUNCTION

The appliance cannot be switched on; any cycle which is in

progress is interrupted and the appliance goes into an alarm

state. Reference icon: n. 14.

VOLUNTARY INTERRUPTION

The user can switch off the appliance at any moment using

button 17. In this case, all the cycles, except the bottle and

can cycles, go into an alarm state. Reference icon: n.13.

LOW YIELD

In cases where the chill blaster does not reach the temperature

within the defined times, a warning will be activated that the

cycle may not have been completed correctly.

The cell should reach the set temperature for the blast chiller

yield alarm threshold parameter or the deep-freeze yield alarm

threshold parameter, respectively, (approximately 5°C less

than the set temperature of the compressor cut-off) within the

set time. The time is the percentage of cycle time indicated by

the yield percentage parameter (in cycles with the food probe,

the percentage is calculated in comparison with the blast chiller

duration parameter or deep-freeze duration parameter which

give a maximum cycle time).

If this does not occur, the cycle is interrupted, but it continues

for the set time and the standard maintenance cycle also takes

place, but the end of cycle warning remains and must be

cancelled in order to start another cycle.