Pay attention as to how the drip-tray is positioned.

 

6.11 BREAKDOWN ALARM

If the appliance is blocked by one or more causes, the system

will go into alarm state and icons no.

07/08/09/10/11/12/13/14/15/16 will all flash at the same

time; when any of the alarm buttons is pressed, only one of

the icons will continue flashing, thus indicating the cause of the

alarm. Only in the case of a low yield signal will the appliance

give an indication of the problem, but the cycle and any

maintenance period will, however, be brought to an end by

implementing the alarm state only at the end of the cycle.

Interruption due to the door being open: lights up icon no. 15

Interruption due to lack of voltage: lights up icon no. 16.

Interruption due to voluntary cycle interruption: lights up icon

no. 13.

Interruption due to low yield: lights up icon no. 8.

Interruption due to chamber probe malfunction: lights up icon

no. 14.

Interruption due to core probe malfunction: lights up icon no. 9

The alarm state is cancelled by pressing down buttons 1 and 6

for a few seconds until a double buzzer is heard; the icons will

stop flashing and the appliance should be programmed again.

The same operation should be carried out if the appliance is

blocked by a voluntary interruption of a cycle before its

programmed end.

Figure 8

25

Advertising