Bird Technologies 8890-400 Series Manuale d'uso

Pagina 23

Advertising
background image

2. Stand the unit on its back end with the connec-

tor end up.

+

Note: In this position there is no danger of the

coolant pouring out through the socket plug

hole.

3. Remove the socket plug located just above the

connector assembly. Use a 9/16 inch hex

wrench.

4. Replace the plug with the thermoswitch. Use

an acceptable pipe sealing compound sparingly

on the external threads only of the ther-

moswitch.

+

Note: Do not contaminate the coolant with pipe

sealing compound.

5. Check the unit for coolant leaks.

While following the instructions below for connecting the

thermoswitch, refer to figure 7.

1.

Unscrew the larger knurled ring-nut (A) at the

lower end of the coupling jack assembly. Pull it

off from the thermoswitch jack (B). Unscrew

the small knurled cover fitting (C) from the

base plug (D) of the connector to release the

base.

2. Thread the interlock wires through the clamp

(E) with the washers (F) inside and with its

treaded fitting in place. Service the interlock

wire with short tips, use spaghetti sleeves over

the wire ends if needed. Then securely solder

13

Installation

O-Ring Seal

Figure 6

Vent Plug

Advertising