Ther moswitch. 12, Thermoswitch – Bird Technologies 8890-400 Series Manuale d'uso

Pagina 22

Advertising
background image

Thermoswitch

As an optional item, the dummy load may be provided with

an interlock thermoswitch assembly, P/N 8890-008. When

installed in the radiator, it will prevent possible damage oc-

curring from accidental transmitted power overload or

equipment malfunction. Being normally closed, the ther-

moswitch opens at a maximum safe temperature of +236°C

(+457°F). Connected in series with the transmitted inter-

lock, it cuts off transmitter power if the coolant temperature

exceed this value. The assembly consists of a thermoswitch

body, P/N 8890-005 with a coupling jack, P/N 2450-018 at-

tached.

WARNING

Before placing the unit into operation, remove the

shipping plug at the top of radiator, near front,

substitute with the specially shielded breather plug.

Use a 3/4 inch flat wrench for this purpose - do not

lose the O-Ring Seal.

This vent hole must remain open at all times when

the unit is in operation or cooling. Failure to do this

could result in damage to the equipment and endanger

the operator’s safety. The use of the vent plug also

protects the filler opening against intrusion of foreign

material while allowing unobstructed venting of the

tank. The shipping plug (with O-Ring seal) should be

put back in place whenever the unit is to be

transported. Be sure to check this plug.

To field install the thermoswitch, follow these instructions:

1. Replace the vent plug with the shipping plug

first, refer to figures 5 and 6 for identification

of plugs.

12

Bird Model 8890-400 Series Termaline Wattmeter

O-ring seal

Figure 5

Shipping Plug