I/o connections, Installation, User controls – AJA UDC Manuale d'uso

Pagina 6: I/o connections installation user controls

Advertising
background image

6

I/O Connections

UDC Mini-Converter

Installation

Typically, UDC installation consists of the following steps:

1. Ensure the UDC is disconnected from power.

2. Connect video equipment to the converter BNCs and HDMI connector.

3. Connect audio equipment to RCA connectors (optional)

4. Apply +5 to +20 VDC power to the converter (AJA power supply model

DWP or DWP-U).

5. The UDC will now run using the default factory settings. If you wish to alter

the factory settings, see the following User Controls section.

User Controls

The UDC can be used right out of the box for many applications, since it is
designed to recognize inputs and perform standard actions automatically.
However, you can also manually configure the UDC using either of two methods:

“Mini Config”software application supplied for PCs and Macs

DIP switches accessible via a cutout on the back of the UDC case

One of the DIP switches is a “Local/Remote” switch. When in the “Local” mode,
the remaining DIP switches support a subset of the user controls. When in the
“Remote” mode, the normal Mini-Converter non-volatile registers control the unit
(as last set).

SD/HD/3G-SDI

+ 5 to +20 VDC

Power

Input

2-Channel

Unbalanced

Analog Audio

(RCA-style Jacks)

HDMI Output

Input 1 BNC

Reference Input

USB

Port

Red: Lock to HD-SDI
Green: Lock to SD-SDI
Amber: Lock to 3G

LOCK LED

SD/HD/3G-SDI

Output

Advertising