12

Alignment

Whenever possible, alignments should be made with
oscillator shields and circuit boards firmly affixed
in place. Also, the test equipment must be thorough-
ly warmed up before beginning.

Note: Signal levels in dB referred to in the alignment

procedure are based on 0dBµ = 0.5µV.

Set up the test equipment as shown below, and ap-
ply 13.8V DC power to the transceiver.

The VX-1700 must be programmed for use in the
intended system before alignment is attempted. The
frequency and other parameters are loaded from the
file during the alignment process.

In order to facilitate alignment over the complete
operating range of the equipment, it is recommend-
ed that the channel data first be uploaded and then
stored to disk. Alignment Channel data should then
be downloaded. The original data can be replaced
at the end of the alignment process.

Reference & Local Alignment

PLL R

EFERENCE

F

REQUENCY

A

LIGNMENT

Connect the Frequency Counter to pin 4 of Q1062
on the MAIN Unit.
Adjust X1003 on the MAIN Unit for 22.625 MHz
±10 Hz on the frequency Counter.

2

ND

L

OCAL

O

UTPUT

L

EVEL

Connect the RF millivoltmeter to TP1043 on the
MAIN Unit.

Adjust T1013 on the MAIN Unit for 160 mVrms
(±50 mVrms) on the RF millivoltmeter.

PLL Alignment

VCO VCV A

LIGNMENT

Connect the DC voltmeter to TP1048 on the MAIN
Unit, and referring to the Table below, switch the
transceiver to each channel listed. Then adjust the
listed component for the required voltage or con-
firm that the correct voltage is present.

PLL O

UTPUT

L

EVEL

Connect the RF millivoltmeter to TP1039 on the
MAIN Unit, then tune the radio to 7.500 MHz.
Confirm that the output level is more than 10
dBm.

Tune to

13.499 MHz

0.100 MHz

29.999 MHz

13.5000 MHz

Adjust or Confirm

Adjust T1066

Confirm

Adjust T1067

Confirm

For

5.2 V ± 0.1 V

More than 0.6 V

5.3 V ± 0.1 V

More than 0.5 V

Transceiver

Inline

Wattmeter

Power Supply

13.8 VDC

Frequency

Counter

RF

Signal Generator

50-ohm

Dummy Load

TUNER

COM Port

CE77 Programming Software

ANT

RF Sampling

Coupler

INPUT

CT-62

Programming Cable

Advertising