4

25-pin Connector Pinout for DS4800


The table below gives the pinout of the 25-pin male D-sub connector for connection to the power supply and
input/output signals. Use this pinout when the DS4800 reader is connected by means of the 25-pin connector:

13

25

14

1

Figure 2 - 25-pin Male D-sub Connector


25-pin D-sub male connector pinout

Pin Name

Function

13, 9

Vdc

Power supply input voltage +

25, 7

GND

Power supply input voltage -

1

CHASSIS

Cable shield connected to chassis

18

I1A

External Trigger A (polarity insensitive)

19

I1B

External Trigger B (polarity insensitive)

6

I2A

Input 2 A (polarity insensitive)

10

I2B

Input 2 B (polarity insensitive)

8

O1+

Output 1 +

22

O1-

Output 1 -

11

O2+

Output 2 +

12

O2-

Output 2 -

20 RX

Auxiliary

RS232

RX

21 TX

Auxiliary

RS232

TX

23

ID+

ID-NET™ network +

24 ID-

ID-NET™

network

-

14, 15, 16, 17

NC

Not Connected

Pin Name

RS232

RS485

Full-Duplex

RS485

Half-Duplex

2 TX

TX+

RTX+

3 RX

*RX+

4 RTS

TX-

RTX-

5

MAIN INTERFACE

(SW SELECTABLE)

CTS

*RX-


* Do not leave floating, see Reference Manual for connection details.