DS4800 QUICK GUIDE

3

STEP 1 – CONNECT THE SYSTEM


To connect the system in a Stand Alone configuration, you need the hardware indicated in Figure 1. In this layout
the data is transmitted to the Host on the main serial interface. In Local Echo communication mode, the RS232
auxiliary interface can be used to transmit data independently from the main interface selection. When On-Line
Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object
enters its reading zone.

Figure 1 – DS4800 in Stand Alone Layout


CBX100/500 Pinout for DS4800


The table below gives the pinout of the CBX100/500 terminal block connectors. Use this pinout when the DS4800
reader is connected by means of the CBX100/500:

CBX100/500 Terminal Block Connectors

Power

Outputs

Vdc

Power Supply Input Voltage +

+V

Power Source - Outputs

GND

Power Supply Input Voltage -

-V

Power Reference - Outputs

Earth

Protection Earth Ground

O1+

Output 1 +

O1-

Output 1 -

Inputs

O2+

Output 2 +

+V

Power Source – External Trigger

O2-

Output 2 -

I1A

External Trigger A (polarity insensitive)

Auxiliary Interface

I1B

External Trigger B (polarity insensitive)

TX

Auxiliary Interface TX

-V

Power Reference – External Trigger

RX

Auxiliary Interface RX

+V

Power Source – Inputs

SGND

Auxiliary Interface Reference

I2A

Input 2 A (polarity insensitive)

ID-NET™

I2B

Input 2 B (polarity insensitive)

REF

Network Reference

-V

Power Reference – Inputs

ID+

ID-NET™ network +

Shield

ID-

ID-NET™ network -

Shield

Network Cable Shield

Main Interface

RS232

RS485 Full-Duplex

RS485 Half-Duplex

TX

TX+

RTX+

RTS

TX-

RTX-

RX

*RX+

CTS

*RX-

SGND

SGND

SGND

* Do not leave floating, see Reference Manual for connection details.

CAUTION

Do not connect GND, SGND and REF to different (external) ground references. GND, SGND
and REF are internally connected through filtering circuitry which can be permanently
damaged if subjected to voltage drops over 0.8 Vdc.

DS4800

Host

PG 6000

P.S.

*

* Presence Sensor

(for On-Line mode)

CBX100/500

I/O, AUX

MAIN