Reading performance, Technical features – Datalogic Scanning DS4800 Manuale d'uso

Pagina 16

Advertising
background image

DS4800 QUICK GUIDE

16

READING PERFORMANCE

Version

Reading Distance

Max Code Resolution

mm (mils)

Speed

scans/s

F = 30

20 cm (7.9 in) - 47 cm (18.5 in) on 0.50 mm (20 mils) codes

0.20 (8)

800

F = 40

25 cm (9.8 in) - 68 cm (26.8 in) on 0.50 mm (20 mils) codes

0.30 (12)

800

F = 60

40 cm (16.7 in) - 100 cm (39.4 in) on 0.50 mm (20 mils) codes

0.38 (15)

800


TECHNICAL FEATURES

ELECTRICAL FEATURES

Power Supply

10 to 30 Vdc

Max. Consumption

0.6 to 0.2 A; 6 W

Main Serial Interfaces

Baud Rate

Programmable:
RS232, RS485 FD and HD
1200 to 115200

Auxiliary Interface

Baud Rate

RS232
1200 to 115200

ID-NET™ Interface

Baud Rate

RS485 Half Duplex
Up to 1Mbaud

Inputs

Input 1 (External Trigger), Input 2
Voltage
Current Consumption
Minimum Pulse Duration


Optocoupled, polarity insensitive
10 to 30 Vdc
12 mA max.
5 ms

Outputs

Output 1, Output 2
V

CE

Collector Current
V

CE Saturation

Power Dissipation


Optocoupled
30 Vdc max.
40 mA continuous max.; 130 mA pulsed max.
1V at 10 mA max.
80 mW max. at 45 °C (ambient temperature)

OPTICAL FEATURES

Light Source

Semiconductor laser diode

Wavelength

In the range 630 to 680 nm

Safety Class

Class 2 – EN 60825-1; CDRH

READING FEATURES
Scan Rate (software programmable)

600 to 900 scans/sec

Aperture Angle

50°

Maximum Reading Distance
Maximum Resolution

See reading diagrams

ENVIRONMENTAL FEATURES

Operating Temperature

0° to +50 °C (+32° to +122 °F) c

Storage Temperature

-20° to +70 °C (-4° to +158 °F)

Humidity max.

90% non condensing

Vibration Resistance
EN 60068-2-6

14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
2 g @ 70 to 200 Hz; 2 hours on each axis

Shock Resistance
EN 60068-2-27

30 g; 11 ms;
3 shocks on each axis

Protection Class

IP65

PHYSICAL FEATURES

Dimensions

85 x 101 x 42 mm (3.3 x 4 x 1.7 in)

Weight

570 g (20.1 oz)

USER INTERFACE
LED Indicators

Ready, Good, Trigger, Com, Status, Power On

Multi-function Key

X-PRESS™ button

Display

2 lines x 16 characters

menu and diagnostic messages configurable in various languages

c

If the reader is used in high temperature environments (over 40 °C), use of the Beam Shutter is advised (see the Genius™
configuration program) and/or a thermally conductive support (such as the metal bracket provided).

Advertising