1 building in, 2 electrical installation, 3 cable – Electrolux EOB3400BOR Manuale d'uso

Pagina 22

Advertising
background image

12.1 Building In

573

594

5

589

558

548

20

min. 550

20

590

min. 560

min. 550

min. 560

600

20

A B

12.2 Electrical installation

WARNING!
Only a qualified person must do
the electrical installation.

The manufacturer is not responsi-
ble if you do not follow the safety
precautions from the chapter
"Safety Information".

This appliance is supplied with a main
plug and a main cable.

12.3 Cable

Cable types applicable for installation or
replacement: H07 RN-F, H05 RN-F, H05
RRF, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
For the section of the cable refer to the
total power (on the rating plate) and to the
table:

Total power

Section of the ca-

ble

maximum 1380
W

3 x 0.75 mm²

maximum 2300
W

3 x 1 mm²

maximum 3680
W

3 x 1.5 mm²

The earth cord (green / yellow cable) must
be 2 cm longer than phase and neutral
cables (blue and brown cables).

22 www.electrolux.com