Controlli e funzioni ita uk controls and functions, Alimentazione power supply – FBT ProMaxX Manuale d'uso

Pagina 10

Advertising
background image

O

TO

PREVENT

THE

RISK

OF

FIRE

OR

ELECTRIC

SHOCK

DO

NOT

OPEN.

NEVER

EXPOSE

THIS

EQUIPMENT

TO

RAIN

OR

MOISTURE.

CAUTION:

220-230V 50/60Hz

T4AL - 250V

640W

0

0.5

1

1.5

2

2.5

3

3.5

DELAY

mt.

PRESET

LEVEL

+6dB

0

0

0

IN

LINK

PEAK

ON

GND

LIFT

OFF

ON

PHASE

180˚

LMT

PRT/

1-ORIGINAL 100Hz

4-

140Hz

5-PUNCH

100Hz

6-

80Hz

2-

80Hz

3-

120Hz

7-

120Hz

8-

140Hz

MADE IN ITALY

15Sa

1

2

3

4

5

6

7

8

CONTROLLI E FUNZIONI

ITA

UK

CONTROLS AND FUNCTIONS

8

LEVEL:

DELAY:

PRESET:

GND LIFT:

ON:

PHASE:

PEAK:

L M T / P R T:

IN-LINK:

regola il livello generale del segnale
controllo di una linea di ritardo digitale che agisce

sul segnale di ingresso; in questo modo è possibile
compensare il disallineamento sul piano verticale di sub e
satellite. Il delay è espresso in metri e va da 0.5 a 3.5 metri a
passi di 50cm

seleziona 8 preset ad ognuno dei quali

corrisponde una configurazione di diffusori in base alle
preferenze personali e all’acustica dell’ambiente di ascolto
(vedi descrizione nella sezione PRESET)

interruttore per la separazione elettrica tra il

circuito di massa e il circuito di terra onde evitare possibili
“loop” di massa causa di fastidiosi ronzii

indica l’attivazione del sistema

il controllo Phase consente di ottimizzare

l’allineamento di fase, cioè di ottenere una risposta in
frequenza uniforme nella zona di incrocio tra sub e satellite.
Nella posizione 0° l’emissione sonora del sub è in fase con
il segnale di ingresso; nella posizione 180° l’emissione
sonora è in contro-fase con il segnale di ingresso; questo
controllo consente di ottenere ulteriore flessibilità nella
messa a punto del subwoofer ottimizzandone le prestazioni

l’accensione di questo led indica che il livello del

segnale è prossimo alla saturazione

l ’ a c c e n s i o n e

d e l

l e d

i n d i c a

i l

malfunzionamento del sistema dovuto ad un guasto
dell’amplificatore interno o all’intervento dei circuiti di
limitazione per evitare sovraccarico termico

Prese di ingresso/uscita bilanciate collegate in

parallelo; “IN” consente il collegamento di un segnale
preamplificato come ad esempio quello in uscita da un
mixer; “LINK” permette il collegamento di più diffusori con lo
stesso segnale

LEVEL:

DELAY:

PRESET:

GND LIFT:

ON:

PHASE:

PEAK:

LMT/PRT:

IN-LINK:

adjusts the signal general level

control of a digital delay line acting on the input

signal; in this way it is possible to make up for the vertical
misalignment of sub and satellite. The delay is expressed in
metresw and goes from 0.5 to 3.5 mt. with 50cm steps

select 8 preset, each of whom corresponds to a

specific speaker configuration according to user’s personal
preferences and to the acoustics of the listening area (see
PRESET section)

a switch for the electric separation between

the ground and earth circuits; this can be useful in order to
remove the irritating noises caused by ground loops

indicates that the system is on

when this led lights up it indicates that the signal is

reaching saturation

if this led lights up there is a system

malfunction due to an internal amplifier failure or to the
intervention of current limiting circuits against thermal
overload

balanced input/output sockets connected in

parallel mode; “IN” allows to connect a pre-amplified signal
such as that coming, for instance, from mixer output; “LINK”
allows to connect multiple speakers to the same signal.

the Phase control allows to optimize phase

alignment, i.e. to obtain a uniform frequency response in
the crossover area between the sub and the satellite. When
it is set at 0° the sound emission is in phase with the input
signal; when it is set at 180° the sound emission is in
counterphase with the input signal; thanks to this control
subwoofer adjustment will be even more flexible with a
consequent performance optimization

ALIMENTAZIONE

POWER SUPPLY

Prima di collegare l’apparecchio alla rete
elettrica accertarsi che la tensione di
alimentazione corrisponda con quella
indicata nel retro dell’unità. La presa di
alimentazione comprende anche il vano
portafusibile; i fusibili difettosi devono
essere assolutamente sostituiti con altri
che abbiano valore e caratteristiche
elettriche uguali.

Before connecting the apparatus to the
mains, make sure the supply voltage
matches the one indicated on the back of
the apparatus. The power socket also
included a fuse box; faulty fuses shall be
replaced only with fuses having the same
electrical features and value.

TO PREVENT THE RISK OF FIRE OR ELECTRIC
SHOCK DO NOT OPEN. NEVER EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.

CAUTION:

220-230V 50/60Hz

T4AL - 250V

640W

TO PREVENT THE RISK OF FIRE OR ELECTRIC
SHOCK DO NOT OPEN. NEVER EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.

CAUTION:

120V 60Hz

T10AH - 250V

640W

Advertising