DIVAtop HC

35

EN

cod. 3540S840 - 02/2010 (Rev. 00)

5.2 Water circuit

fig. 24 - Water circuit

7

Gas inlet

10

System delivery

11

System return

14

Safety valve

20

Burner assembly

27

Copper exchanger

32

Heating circulating pump

36

Automatic air vent

44

Gas valve

56

Expansion tank

74

System filling cock

78

Anti-backflow device

81

Ignition and detection electrode

95

Diverter valve

126

Fume thermostat

209

Hot water tank delivery

210

Hot water tank return

241

Automatic bypass

246

Pressure transducer

278

Double sensor (Safety + Heating)

5.3 Technical data table

The column on the right gives the abbreviation used on the dataplate.

5.4 Diagrams

Pressure - power diagrams DIVAtop HC 24

A

LPG

B

NATURAL GAS

Circulating pump head / pressure losses DIVAtop HC 24

A

Boiler pressure losses

1 - 2 - 3

Circulating pump speed

Pressure - power diagrams DIVAtop HC 32

A

LPG

B

NATURAL GAS

Circulating pump head / pressure losses DIVAtop HC 32

A

Boiler pressure losses

1 - 2 - 3

Circulating pump speed

Data

Unit

DIVAtop HC 24

DIVAtop HC 32

Max. heating capacity

kW

25.8

34.4

(Q)

Min. heating capacity

kW

8.3

11.5

(Q)

Max. Heat Output in heating

kW

23.5

31.3

(P)

Min. Heat Output in heating

kW

7.0

9.7

(P)

Burner nozzles G20

no.x Ø

11 x 1.35

15 x 1.35

Gas supply pressure G20

mbar

20

20

Max. pressure downstream of gas valve (G20)

mbar

12.0

12.0

Min. pressure downstream of gas valve (G20)

mbar

1.5

1.5

Max. gas delivery G20

m

3

/h

2.73

3.64

Min. gas delivery G20

m

3

/h

0.88

1.22

Burner nozzles G31

no.x Ø

11 x 0.79

15 x 0.79

Gas supply pressure G31

mbar

37

37

Max. pressure downstream of gas valve (G31)

mbar

35.0

35.0

Min. pressure downstream of gas valve (G31)

mbar

5.0

5.0

Max. gas delivery G31

kg/h

2.00

2.69

Min. gas delivery G31

kg/h

0.65

0.90

Efficiency class Directive 92/42 EEC

-

NOx emission class

-

3 (<150 mg/kWh)

3 (<150 mg/kWh)

(NOx)

Max. working pressure in heating

bar

3

3

(PMS)

Min. working pressure in heating

bar

0.8

0.8

Max. heating temperature

°C

90

90

(tmax)

Heating water content

litres

1.0

1.2

Heating expansion tank capacity

litres

8

10

Heating expansion tank prefilling pressure

bar

1

1

56

81

44

20

27

14

32

11

10

7

210

278

95

241

246
36

209

74

78

126

Protection rating

IP

X5D

X5D

Power supply voltage

V/Hz

230V/50Hz

230V/50Hz

Electrical power input

W

110

90

DHW electrical absorption
(with optional hot water tank installed)

W

110

90

Empty weight

kg

32

30

Type of unit

B

11BS

PIN CE

0461BR0843

Data

Unit

DIVAtop HC 24

DIVAtop HC 32

B

A

0

1

2

3

4

5

6

7

0

500

1.000

1.500

2.000

Q [l/h]

H [m H

2

O]

A

3

2

1

A

B

0

1

2

3

4

5

6

7

0

500

1.000

1.500

2.000

Q [l/h]

H [m H

2

O]

A

3

1

2