Divatop hc, 34 en – FERROLI Divatop H C User Manual

Page 34

Advertising
background image

DIVAtop HC

34

EN

cod. 3540S840 - 02/2010 (Rev. 00)

Table of faults

Table. 2

5. TECHNICAL DATA AND CHARACTERISTICS

5.1 General view and main components

fig. 22 - General view DIVAtop HC 24

fig. 23 - General view DIVAtop HC 32

7

Gas inlet

10

System delivery

11

System return

14

Safety valve

19

Combustion chamber

20

Burner assembly

21

Main nozzle

22

Burner

26

Combustion chamber insulation

27

Copper exchanger

32

Heating circulating pump

36

Automatic air vent

44

Gas valve

56

Expansion tank

74

System filling cock

78

Anti-backflow device

81

Ignition and detection electrode

95

Diverter valve

126

Fume thermostat

145

Pressure gauge

209

Hot water tank delivery

210

Hot water tank return

246

Pressure transducer

278

Double sensor (Safety + Heating)

Code

fault

Fault

Possible cause

Recommended cure

A01

No burner ignition

No gas

Check the regular gas flow to the
boiler and that the air has been
eliminated from the pipes

Ignition/detection electrode fault

Check the wiring of the electrode
and that it is correctly positioned
and free of any deposits

Defective gas valve

Check and change the gas valve

Ignition power too low

Adjust the ignition power

A02

Flame present signal with
burner off

Electrode fault

Check the ionisation electrode
wiring

Card trouble

Check the card

toA03

Over-temperature
protection trips

Heating sensor damaged

Check the correct positioning and
operation of the heating sensor

No water circulation in the system

Check the circulator

Air in the system

Vent the system

F04

Fume thermostat
activated (after activation of
the fume thermostat, boiler
operation is prevented for
20 minutes)

Fume thermostat contact open

Check the thermostat

Wiring disconnected

Check the wiring

Flue not correctly sized or
obstructed

Change the flue

A06

No flame after the ignition
phase

Low pressure in the gas system

Check the gas pressure

Burner minimum pressure setting

Check the pressures

F10

Delivery 1 sensor fault

Sensor damaged

Check the wiring or replace the
sensor

Wiring shorted

Wiring disconnected

F11

Tap water sensor fault

Sensor damaged

Check the wiring or replace the
sensor

Wiring shorted

Wiring disconnected

F14

Delivery 2 sensor fault

Sensor damaged

Check the wiring or replace the
sensor

Wiring shorted

Wiring disconnected

F34

Supply voltage under
170V.

Electric mains trouble

Check the electrical system

F35

Irregular mains frequency

Electric mains trouble

Check the electrical system

F37

Incorrect system water
pressure

Pressure too low

Fill the system

Sensor damaged

Check the sensor

F39

External sensor fault

Probe damaged or wiring shorted

Check the wiring or change the
sensor

Sensor disconnected after activat-
ing the sliding temperature

Reconnect the external sensor or
disable the sliding temperature

F40

Incorrect system water
pressure

Pressure too high

Check the system

Check the safety valve

Check the expansion tank

A41

Sensor positioning

Delivery sensor detached from pipe

Check the correct positioning and
operation of the heating sensor

F42

Heating sensor fault

Sensor damaged

Change the sensor

F43

Exchanger protection trips.

No system H

2

O circulation

Check the circulator

Air in the system

Vent the system

F47

System water pressure
sensor fault

Wiring disconnected

Check the wiring

F50

Modureg fault

Wiring disconnected

Check the wiring

44

32

246

36

14

26

19

27

56

78

81

20

21

22

278

95

10

209

7

210

11

145

74

126

44

32

246

36

14

26

19

27

56

78

81

20

21

22

278

95

10

209

7

210

11

145

74

126