23

InfraStruXure Central Installation Manual

E2017

Timer Fail

Timer refresh failure.

E2018

Prog Timer

Programmable interval timer error.

E2019

Parity Error

Parity error.

E201A

SIO Err

SIO failure.

E201B

Kybd Controller

Keyboard controller failure.

E201C

SMI Init

System management interrupt (SMI) initialization failure.

E201D

Shutdown Test

BIOS shutdown test failure.

E201E

POST Mem Test

BIOS POST memory test failure.

E201F

DRAC Config

Dell remote access controller (DRAC) configuration failure.

E2020

CPU Config

CPU configuration failure.

E2021

Memory Population

Incorrect memory configuration. Memory population order
incorrect.

E2022

POST Fail

General failure after video.

E2110

MBE Crd # DIMM ## &

##

One of the DIMMs in the set implicated by "## & ##" has had a
memory multi-bit error (MBE). If no memory card is present,
the "Crd #" string is left out of the message.

E2111

SBE Log Disable Crd #

DIMM ##

The system BIOS has disabled memory single-bit error (SBE)
logging, and will not resume logging further SBEs until the
system is rebooted. "##" represents the DIMM implicated by the
BIOS. If no memory riser card is present, the "Crd #" string is
left out of the message.

E2112

Mem Spare Crd # DIMM

##

The system BIOS has spared the memory because it has
determined that the memory had too many errors. "## & ##"
represents the DIMM pair implicated by the BIOS. If no
memory card is present, the "Crd #" string is left out of the
message.

E2113

Mem Mirror Crd # DIMM

## & ##

The system BIOS has disabled memory mirroring because it has
determined that one half of the mirror has had too many errors.
"## & ##" represents the DIMM pair implicated by the BIOS. If
no memory card is present, the "Crd #" string is left out of the
message.

E2118

Fatal NB Mem CRC

One of the connections in the Fully Buffered DIMM (FBD)
memory subsystem link on the Northbound side has failed.

E2119

Fatal SB Mem CRC

One of the connections in the FBD memory subsystem link on
the Southbound side has failed.

I1910

Intrusion

System cover has been removed.

I1911

>3 ERRs Chk Log

LCD overflow message.

A maximum of three error messages can display sequentially on
the LCD. The fourth message displays as the standard overflow
message.

I1912

SEL Full

System Event Log is full of events, and is unable to log any
more events.

W1228

ROMB Batt < 24hr

Warns predictively that the RAID battery has less than 24 hours
of charge left.

Advertising