Appendix b: diagnostic messages, Message listing, Overview – APC AP9475 Manuale d'uso

Pagina 25

Advertising
background image

21

InfraStruXure Central Installation Manual

Appendix B: Diagnostic Messages

Message Listing

Overview

The system's control panel LCD provides status messages to signify when the system is operating
correctly or when the system needs attention.

The LCD lights blue to indicate a normal operating condition, and lights amber to indicate an error
condition. The LCD scrolls a message that includes a status code followed by descriptive text..

The following table lists the potential error messages along with a short description of the condition
described by the message.

Code

Text

Causes

N/A

SYSTEM NAME

The SYSTEM NAME displays under the following conditions:
• The system is turned on.
• The power is off and active POST errors are displayed.

E1000

FAILSAFE, Call

Support

Contact APC Customer Support at a number on the back cover
of this manual

E1114

Temp Ambient

Ambient system temperature is out of acceptable range.

E1116

Temp Memory

Memory has exceeded acceptable temperature and has been
disabled to prevent damage to the components.

E12nn

xx PwrGd

Specified voltage regulator has failed.

E1210

CMOS Batt

CMOS battery is missing, or the voltage is out of acceptable
range.

E1211

ROMB Batt

RAID battery is either missing, bad, or unable to recharge due to
thermal issues.

E1229

CPU # VCORE

Processor # VCORE voltage regulator has failed.

E1310

RPM Fan ##

RPM of specified cooling fan is out of acceptable operating
range.

E1313

Fan Redundancy

The system is no longer fan-redundant. Another fan failure will
put the system at risk of over-heating.

E1410

CPU # IERR

Specified microprocessor is reporting an internal error.

E1414

CPU # Thermtrip

Specified microprocessor is out of acceptable temperature range
and has halted operation.

E1418

CPU # Presence

Specified processor is missing or bad, and the system is in an
unsupported configuration.

E141C

CPU Mismatch

Processors are in a configuration unsupported by APC.

E141F

CPU Protocol

The system BIOS has reported a processor protocol error.

E1420

CPU Bus PERR

The system BIOS has reported a processor bus parity error.

E1421

CPU Init

The system BIOS has reported a processor initialization error.

E1422

CPU Machine Chk

The system BIOS has reported a machine check error.

E1610

PS # Missing

No power is available from the specified power supply;
specified power supply is improperly installed or faulty.

E1614

PS # Status

No power is available from the specified power supply;
specified power supply is improperly installed or faulty.