22

E1618

PS # Predictive

Power supply voltage is out of acceptable range; specified
power supply is improperly installed or faulty.

E161C

PS # Input Lost

Power source for specified power supply is unavailable, or out
of acceptable range.

E1620

PS # Input Range

Power source for specified power supply is unavailable, or out
of acceptable range.

E1624

PS Redundancy

The power supply subsystem is no longer redundant. If the last
supply fails, the system will go down.

E1710

I/O Channel Chk

The system BIOS has reported an I/O channel check.

E1711

PCI PERR B## D## F##

PCI PERR Slot #

The system BIOS has reported a PCI parity error on a
component that resides in PCI configuration space at bus ##,
device ##, function ##.

The system BIOS has reported a PCI parity error on a
component that resides in the specified PCI slot.

E1712

PCI SERR B## D## F##

PCI SERR Slot #

The system BIOS has reported a PCI system error on a
component that resides in PCI configuration space at bus ##,
device ##, function ##.

The system BIOS has reported a PCI system error on a
component that resides in the specified slot.

E1714

Unknown Err

The system BIOS has determined that there has been an error in
the system, but is unable to determine its origin.

E171F

PCIE Fatal Err B##

D## F##

PCIE Fatal Err Slot #

The system BIOS has reported a PCIe fatal error on a
component that resides in PCI configuration space at bus ##,
device ##, function ##.

The system BIOS has reported a PCIe fatal error on a
component that resides in the specified slot.

E1810

HDD ## Fault

The SAS subsystem has determined that hard drive ## has
experienced a fault.

E1811

HDD ## Rbld Abrt

The specified hard drive has experienced a rebuild abort.

E1812

HDD ## Removed

The specified hard drive has been removed from the system.

E1913

CPU & Firmware

Mismatch

The BMC firmware does not support the CPU.

E1A11

PCI Rsr Config

PCI risers are not configured correctly; some invalid
configurations may prevent the system from turning on.

E1A12

PCI Rsr Missing

One or all of the PCI risers are missing, preventing the system
from turning on.

E1A14

SAS Cable A

SAS cable A is missing or bad.

E1A15

SAS Cable B

SAS cable B is missing or bad.

E2010

No Memory

No memory is installed in the system.

E2011

Mem Config Err

Memory detected, but is not configurable. Error detected during
memory configuration.

E2012

Unusable Memory

Memory is configured, but not usable. Memory subsystem
failure.

E2013

Shadow BIOS Fail

The system BIOS failed to copy its flash image into memory.

E2014

CMOS Fail

CMOS failure. CMOS RAM not functioning properly.

E2015

DMA Controller

DMA controller failure.

E2016

Int Controller

Interrupt controller failure.