AFP SWITCH
• OFF
(reset): The anti-feedback function is turned off, the microphone

works in standard

mode and therefore any feedback could occur (just like any traditional

type of microphone). In this position, the yellow AFP LED on the receiver

front panel is off. Note: when the switch is in this position, all filters

previously inserted are eliminated.

• LOW: The anti-feedback function is switched on and the filter intervention

is soft and gradual; the AFP yellow LED is on. This position is recommended

for singing, especially when using a radiomicrophone / hand-held

transmitter and/or in very noisy environments.

• HIGH: The anti-feedback function is switched on and the filter

intervention is quick and decisive; the AFP yellow LED is on. This

position is recommended when using radiomicrophones very close to

loudspeakers or with clip-on microphones or in very quiet environments

(where even the feedback beginning could be annoying).

EXAMPLE - After connecting the receiver (power supply, audio, etc.), set

the AFP switch to the position suitable to the use (i.e. “HIGH” in the case of

a conference in a very quiet environment); make sure that the yellow AFP

LED on the front of the receiver is lit.

No other particular adjustments are necessary: once the transmitter is

switched on, the system is

ready to use.

Let’s suppose now that the speaker moves to another part of the room

while he is speaking.

In case a feedback occurs (due to the loudspeaker volume level and

position or also to the room form and dimensions), this will be immediately

identified and eliminated (instead of increasing exponentially). Moreover,

if the speaker returned to the same point again, the feedback would not

even begin, because one or more filters would have already been inserted

on feedback frequencies.

NOTE - All the filters in memory are eliminated when the microphone

receiver is switched off and also when the AFP switch is set to OFF position.