Main input – RCF UP 2161 Power Amplifier (160W) Manuale d'uso

Pagina 8

Advertising
background image

ENGLISH

DIP 3

DIP 4

DIP 5

MODE

USE (EXAMPLES)

OFF

HIGH
LEVEL

---

HIGH LEVEL (0
dBu)

CD/MP3 players, tuners, message players, phone systems

OFF

LOW
LEVEL

LINE

LINE
(– 20 dBu)

Audio sources having – 20 dBu output level

OFF

LOW
LEVEL

MICRO

MIC

Dynamic microphones

PHANTOM

HIGH
LEVEL

---

HIGH LEVEL
with PHANTOM

Pre-amplified (0 dBu output) paging microphone that needs
‘phantom’ power supply

PHANTOM

LOW
LEVEL

LINE

LINE
with PHANTOM

BM 3001 paging microphone

PHANTOM

LOW
LEVEL

MICRO

MIC
with PHANTOM

Electret microphones

Examples of dip-switch 3, 4, 5 setting:

5

Removable connector:

6

RJ 45 socket (i.e. useful to connect a BM 3001 paging microphone).

N

ote

:

wheN

a

BM 3001

pagiNg

MicrophoNe

is

coNNected

,

it

is

Necessary

to

set

the

dip

-

switches

3, 4

aNd

5

to

the

‘LiNe

with

phaNtoM’

Mode

(

see

4 MaiN iNpUt

settiNgs

throUgh

5

dip

-

switches

).

BM 3001 shall be set to ‘LOCAL’.
Cable with RJ 45 plug:

When a BM 3001 paging microphone is used, it is necessary to choose the ‘LINE
with PHANTOM’ mode (dip-switch no.3 set to PHANTOM, dip-switch no.4 set to
LOW LEVEL, dip-switch no.5 set to LINE).

1

+

hot audio input

2

-

cold audio input

3

GND

ground

4

CMD

priority command (ON: when linked to ground)

Green

Blue

Orange

Orange/White

GND

+

PRIORITY

COMMAND

(TO GND)

Audio

signal

Brown

Brown/White

Green

Blue/White

Blue

Green/White

Orange

Orange/White

1

2

3

4

5

6

7

8

RJ

MAIN INPUT

MAIN INPUT