FINAL CHECKS

Before switching the device on, undertake the following checks:

• If the device has been transported in a non-vertical position (for instance, on its back) or it has
been tipped during installation, check the level of the oil in the pump using the inspection hole.

A


B: 1 - Oil top-up cap 2 - Pump 3 - Oil level

4 - Oil drainage cap



1. Disconnect the machine from the electricity supply.
2. Dismantle the side inspection panel (Fig. A).
3. Check the correct oil level (Fig. B). If necessary, clean any drips and top up the pump with
SW40 oil.

• Check the machine is correctly connected to the electricity supply.

After having completed these checks:

• Check the absorption with an ammeter.
• Carry out at least one complete cycle of vacuum packing for bags.
• Inform the client of the exact use of the device with specific reference to the client's uses and the
needs.