Fast & Fluid LEOLUX Manuale d'uso

Pagina 21

Advertising
background image

FAST & FLUID MANAGEMENT srl
A Unit of Idex Corporation


INTERNAL CANISTERS CLICK-OUT

















• 3 = 3 litres canisters (External).

• 5 = 5 litres canisters (Internal).

• 10 = 10 litres canisters (Internal).





If you want to remove a internal canister you should have to remove first the external canister
positioned immediately at its right side.

After that, to remove one of the internal canisters follow the next procedure.

10

10

5

5

5

5

3

3

3

5

5

3

3

3

3














(Fig.14)

Turn the cut-off cock
in clockwise direction

from the open
position (see picture

fig.14)…











(Fig.15)


…to the close position
(fig.15); in this way it

will be possible to
release the entire

valve & pump group

without any colorant
leakage.











(Fig.16)

Unscrew the locking

nuts of the pump

(fig. 16)












(Fig.17)


and keep out the entire
pump & valve group

(fig.17).



1155306D-it,en - 17/03/06