Watlow Series F4S/D Manuale d'uso

Pagina 44

Advertising
background image

Wa t l o w S e r i e F 4 S / D

P r o g r a m m a z i o n e d e i p r o f i l i

4 . 9

Figura 9a — Diagramma di profilo per Military Standard 810D Test.

Figura 9b — Grafico di Military Standard 810D Test.

Num.

Tipo

Data/giorno, Attesa

Eventi impostati

Orario

Veloc.

Set

Set

Set

Soak

Jump:

Step

Ripetiz.

Step

Step

Step

Ora

1 2 3 4 5 6 7 8

O M S

Pt 1

Pt 2

PID

Garan. Profilo

End

1

Ramp Time

1 sec.

88°F

88%

2

Soak

Process1&2

1 sec.

3

Soak

5 hr.

4

Ramp Time

1 hr.

90°F

85%

5

Ramp Time

1 hr.

93°F

80%

6

Ramp Time

1 hr.

96°F

76%

7

Ramp Time

1 hr.

98°F

73%

8

Ramp Time

1 hr.

100°F 69%

9

Ramp Time

1 hr.

102°F 65%

10

Ramp Time

1 hr.

104°F 62%

11

Ramp Time

1 hr.

105°F 59%

12

Soak

Process1&2

3 hr.

13

Ramp Time

1 hr.

102°F 65%

14

Ramp Time

1 hr.

99°F

69%

15

Ramp Time

1 hr.

97°F

73%

16

Ramp Time

1 hr.

94°F

79%

17

Ramp Time

1 hr.

91°F

85%

18

Ramp Time

1 hr.

90°F

85%

19

Ramp Time

1 hr.

89°F

88%

20

Jump

3

20

21

End

All Off

Advertising