Table of burner and nozzle specifications, Kn3g62 sa/i s – Indesit KN3G62SA(W)-I-S Manuale d'uso
Pagina 20

20
GB
Table of burner and nozzle specifications
S S
R
A
*
At 15°C and 1013 mbar- dry gas
**
Propano
P.C.S. = 50,37 MJ/Kg
***
Butano P.C.S. = 49,47 MJ/Kg
Naturale
P.C.S. = 37,78 MJ/m
3
KN3G62 SA/I S
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nominal
Reduced
(mm)
(mm)
***
**
(mm)
Fast
(Large)(R)
100
3.00
0.7
41
87
218
214
128
286
Semi Fast
(Medium)(S)
75
1.90
0.4
30
70
138
136
104
181
Auxiliary
(Small)(A)
51
1.00
0.4
30
52
73
71
76
95
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
TABLE OF CHARACTERISTSICS
Dimensions (with
drawn guide rails)
width 39 cm
height 34 cm
depth 41 cm
Volume (with
drawn guide rails)
56 l
Useful
measurements
relating to the oven
compartment
width 42 cm
height 23 cm
depth 44 cm
Burners
may be adapted for use with any type
of gas shown on the data plate, which
is located inside the flap or, after the
oven compartment has been opened,
on the left-hand wall inside the oven.
Voltage and
frequency
see data plate
ENERGY LABEL
Directive 2002/40/EC on the label of
electric ovens.
Standard EN 50304
Energy consumption for Natural
convection – heating mode:
Convection;
Declared energy consumption for
Forced convection Class – heating
mode: Baking
This appliance conforms to the
following European Economic
Community directives: 2006/95/EC
dated 12/12/06 (Low Voltage) and
subsequent amendments -
2004/108/EC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments - 93/68/EC
dated 22/07/93 and subsequent
amendments.
2002/96/EC
2009/142/EC of 30/11/09 (Gas)