Burner and nozzle specifications – Hotpoint Ariston PY 640 T (IX)-HA Manuale d'uso

Pagina 16

Advertising
background image

GB

16

Burner and nozzle specifications

Table 1 Liquid Gas Natural Gas

Supply pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20
17
25

Reduced Fast (RR)

Semi Fast (Medium) (S)

Auxiliary (Small) (A)

Triple Crown (TC)

100

75

55

130

0.70

0.40

0.40

1.50

2.60

1.65

1.00

3.30

39

28

28

61

80

64

50

91

189

120

73

240

186

118

71

236

2.60

1.65

1.00

3.60

110 (Y)

96

79

145 (H1)

248

157

95

343

Burner

Diameter

(mm)

Thermal

power

kW

(p.c.s.*)

(Reduced)

Thermal

power

kW

(p.c.s.*)

(Nominal)

Thermal

power

kW

(p.c.s.*)

(Nominal)

By-pass

1/100

(mm)

Nozzle

1/100

(mm)

Nozzle

1/100

(mm)

***

**

Flow*

(g/h)

Flow*

(g/h)

*

At 15°C and 1013 mbar-dry gas

**

Propane

P.C.S. = 50.37 MJ/kg.

***

Butane

P.C.S. = 49.47 MJ/kg.

Natural

P.C.S. = 37.78 MJ/m

3

RR

A

S

TC

TC

PY 640 T /HA

Advertising