Report unit number, Assign unit number, Set number of floats – VEGA VEGAPULS 66 (≥ 2.0.0 - ≥ 4.0.0) enamel Modbus and Levelmaster protocol Manuale d'uso

Pagina 71: Set baud rate

Advertising
background image

71

11 Appendice

VEGAPULS 66 smaltato • Protocollo Modbus e LevelMaster

41368-IT

-121116

Report Unit Number

Request:

Parametri

Length

Code/Data

Report Unit Number

5 characters ASCII

U**N?

Response:

Parametri

Length

Code/Data

Report Level (and Temperature)

6 characters ASCII

UuuNnn

Assign Unit Number

Request:

Parametri

Length

Code/Data

Assign Unit Number

6 characters ASCII

UuuNnn

Response:

Parametri

Length

Code/Data

Assign Unit Number

6 characters ASCII

UuuNOK
uu = new Address

Set number of Floats

Request:

Parametri

Length

Code/Data

Set number of Floats

5 characters ASCII

UuuFn

Response:

Parametri

Length

Code/Data

Set number of Floats

6 characters ASCII

UuuFOK

Se il numero viene impostato su 0, non viene più segnalato alcun livello

Set Baud Rate

Request:

Parametri

Length

Code/Data

Set Baud Rate

8 (12) characters ASCII

UuuBbbbb[b][pds]
Bbbbb[b] = 1200, 9600 (default)
pds = parity, data length, stop bit

(optional)
parity: none = 81, even = 71 (de-

fault), odd = 71

Response:

Parametri

Length

Code/Data

Set Baud Rate

11 characters ASCII

Esempio: U01B9600E71