Alignment tool menu, Common data, Alignment – Vertex Standard VX-900 User Manual

Page 22

Advertising
background image

22

Alignment

portant that you follow the basic alignment sequence
precisely, so that the displayed data and the data
loaded into the transceiver are identical.

Basic Alignment Sequence

1. Enter the alignment mode
2. Upload data from transceiver
3. Align data
4. Download data to transceiver

Alignment Tool Menu

Common Data

The parameters in this section represent "common"
data for all channels. Once these "Common Data"
parameters are correctly aligned, the "T

X

P

OWER

,"

"M

AX

D

EV

," and "S

UB

A

UDIO

D

EV

," can be trimmed for

each channel, if needed.
During alignment, each parameter is adjusted for a
higher or lower value via the computer’s [p] and
[q] keys. When the desired value is reached, type
[ENTER] to lock in the new value.

(0) Common Tx :
The first alignment section adjusts transmit-mode
parameters which are common to all channels.
- [0] F

REQUENCY

This parameter is used to adjust the PLL reference
frequency. From the "(0) Common Tx" section,
press [0] to activate this alignment sequence.

• Press the [space] key on the keyboard to activate

the transmitter.

• Press the [p] or [q] key, as needed, so the counter

frequency is within 100 Hz of the channel center
frequency for the MID channel.

• When the precise frequency is attained, press [EN-

TER

] to lock in the new data.

• Now verify that the HIGH and LOW channels

are also within tolerance.

- [1] H

IGH

This parameter is used to align Tx High power (5W).
From the "(0) Common Tx" section, press [1] to ac-
tivate this alignment sequence.

• Use the [t] or [u] key to select the "MID" fre-

quency channel in the alignment range.

• Press the [space] key on the keyboard to activate

the transmitter.

• Press the [p] or [q] key, as needed, to set the

power output to 5 Watts, as indicated on the ex-
ternal wattmeter.

• When the 5 Watt level is attained, press [ENTER]

to lock in the new data.

- [2] L1

This parameter aligns the L1 power (0.25 W) level.
From the "(0) Common Tx" section, press [2] to ac-
tivate this alignment sequence.

• Press the [space] key on the keyboard to activate

the transmitter.

• Press the [p] or [q] key, as needed, to set the

power output to 0.25 W, as indicated on the ex-
ternal wattmeter.

• When the 0.25 W level is attained, press [ENTER]

to lock in the new data.

- [3] L2

This parameter aligns the L2 power (1 W) level.
From the "(0) Common Tx" section, press [3] to ac-
tivate this alignment sequence.

• Press the [space] key on the keyboard to activate

the transmitter.

• Press the [p] or [q] key, as needed, to set the

power output to 1 Watt, as indicated on the ex-
ternal wattmeter.

• When the 1 Watt level is attained, press [ENTER]

to lock in the new data.

- [4] L3

This parameter aligns the L3 power (2.5 W) level.
From the "(0) Common Tx" section, press [4] to ac-
tivate this alignment sequence.

• Press the [space] key on the keyboard to activate

the transmitter.

• Press the [p] or [q] key, as needed, to set the

power output to 2.5 W, as indicated on the exter-
nal wattmeter.

• When the 2.5 W level is attained, press [ENTER]

to lock in the new data.

- [5] M

AXIMUM

D

EVIATION

This section adjusts the transmitter’s voice devi-
ation level. From the “(0) Common Tx” section,
select [5] to enter this alignment sequence.

Advertising