The alignment tool outline, Alignment, Installation of the alignment tool – Vertex Standard VX-900 User Manual

Page 21: Booting the alignment tool, Entering the alignment mode, Alignment sequence

Advertising
background image

21

Alignment

Whenever possible, alignments should be made with
oscillator shields and circuit boards firmly affixed
in place. Also, the test equipment must be thor-
oughly warmed up before beginning.
Note: Signal levels in dB referred to in the alignment
procedure are based on 0 dBµ EMF = 0.5 µV (closed cir-
cuit).

When connecting the CT-71 plug into the MIC/
SP

jack of the VX-900, you must remove the

plastic cap and its mounting screws prior to
programming. Please remember to re-attach
the cap and screws when the programming is
complete.

Set up the test equipment as shown for transceiver
alignment, and apply 7.5V DC power to the trans-
ceiver.

The alignment tool outline

Installation of the Alignment Tool

The "alignment mode" is a software-based protocol,
accessed by an "Alignment Mode" command from
the computer while switching the transceiver on. It
is operated by the alignment tool automatically.
During use of the alignment mode, normal opera-
tion is suspended. The alignment tool program pro-
vides all needed operation capability.
The alignment tool consists of an executable file
“SVC39.exe” and an accompanying configuration
file “SVC39.cfg” which should be loaded per stan-
dard DOS procedures. Create a suitable directory,
then copy these files from the distribution diskette
into the new directory. For example, if copying the
file from Drive A, use the following DOS command
sequence:

c:\ mkdir align900 [enter]
c:\ cd align900 [enter]
c:\align900\ copy a:SVC39.*

No further installation steps are required. If you wish
to utilize a different name for the alignment direc-
tory, it will not matter to the executable file.

Booting the Alignment Tool

Change to the “align900” directory (or the directory
name you utilized in the previous section). Now type
on the command line: SVC39 [ENTER] to boot the
alignment tool.

Entering the Alignment Mode

To enter the alignment mode, turn the transceiver
off, then press [0] on the computer keyboard. Now,
turn the transceiver back

O

n. When the command

has been successful, a message on the computer
screen will confirm that the transceiver is now in
the “Alignment” mode.
Action of the Switches
When the transceiver is in alignment mode, the [PTT],
[MON], and [DIAL] switches, as well as the Dial, are
disabled. In the Alignment mode, all of the
transceiver’s operation is remotely controlled by the
PC.

Alignment Sequence

Although the data displayed on the computer’s
screen during alignment is temporary data, it is im-

Important Note

The transceiver must be programmed for use in the
intended system before alignment is attempted. The
RF parameters are loaded from the file during the
alignment process.
In order to facilitate alignment over the complete
operating range of the equipment, it is recom-
mended that the channel data in the transceiver be
preset as per the chart below.

Channels

Frequency

(Simplex)

Band-LOW

Band-MID

Band-HIGH

450.000

470.000

485.000

50-ohm

Dummy Load

Inline Wattmeter

Deviation Meter

Frequency

Counter

RF Sampling

Coupler

RF Signal

Generator

Transceiver

Power Supply

7.5V DC

CT-71 connection
Cable

PC

MIC/SP

COM port

Advertising