Eqp eclipse, Eqp220 0dcu, Eqp240 1ne – Det-Tronics PIRECL Infrared Hydrocarbon Gas Detector PointWatch Eclipse Manuale d'uso

Pagina 66: Eqp250 0s am, Eqp220 0uvir, Eqpx330 1, Eqp220 0idc, Eqp21 0 0psm, Eqp220 0uv, Eqp370 0dcio

Advertising
background image

H-6

95-4526

14.1

EQP250

0ARM

13

14

11

12

B

6

10

A

5

9

2

+

3

4

+

1

7

8

COM2

COM1

EQP ECLIPSE

6

3

4

1

5

2

B

11

8

A

10

7

C

ALIBR

A

TE

13

12

9

COM2

COM1

EQP220

0DCU

13

14

11

12

B

6

10

A

5

9

2

3

+

4

1

7

8

COM2

COM1

EQP240

1NE

SHIELD

4

9

6

7

5

8

B

11

3

A

10

2

12

1

COM2

COM1

EQP250

0S

AM

13

14

11

12

B

6

10

A

5

9

OUTPUT 1 –

2

OUTPUT 2 +

3

OUTPUT 2 –

4

OUTPUT 1 +

1

7

8

COM2

COM1

EQP220

0UVIR

3

4

1

2

B

9

6

A

8

5

10

7

COM2

COM1

EQPX330

1

13

3

11

1

12

2

B

14

4

A

15

5

16

6

COM2

COM1

EQP220

0IDC

13

14

11

12

B

6

10

A

5

9

CIRCUIT 1 –

2

CIRCUIT 2 +

3

CIRCUIT 2 –

4

CIRCUIT 1 +

1

7

8

24

VDC –

24

VDC +

SHIELD

COM2

COM1

EQP21

0

0PSM

4

9

24

VDC –

24

VDC +

SHIELD

SHIELD

6

7

5

8

B

11

3

A

10

2

B

2

3

4

C

1

12

1

COM2

COM1

EQP220

0UV

3

4

1

2

B

9

6

A

8

5

10

7

24

VDC –

24

VDC +

24

VDC –

24

VDC +

24

VDC –

24

VDC +

SHIELD

SHIELD

SHIELD

SHIELD

COM2

COM1

B

US B

AR

P3

A

C LINE

N

H

SOLENOIDE SINGOLO

SOLENOIDI DOPPI

EQP370

0DCIO

6

3

5

2

4

1

B

5

2

A

4

1

6

3

COM2

COM1

P1

P2

P3

P4

B

B

C

C

A

A

24

VDC –

24

VDC +

SHIELD

SHIELD

IN–/OUT+

COMMON

+ SUPPL

Y

IN–/OUT+

COMMON

+ SUPPL

Y

IN–/OUT+

COMMON

+ SUPPL

Y

IN–/OUT+

COMMON

+ SUPPL

Y

CH 1

CH 5

B

B

C

C

A

A

CH 2

CH 6

B

B

C

C

A

A

CH 3

CH 7

B

B

C

C

A

A

CH 4

CH 8

CENTR

ALINA

4

2

3

1

B

52

49

A

53

50

TxD

A

59

56

RxD

B

58

55

GND

GND

57

54

51

48

COM2

COM1

P1

P7

P9

P8

P4

P5

1+

5+

5

13

1–

5–

6

14

2+

6+

7

15

2–

6–

8

16

3+

7+

9

17

3–

7–

10

18

4+

8+

11

19

4–

8–

12

20

P2

P3

C

45

NO

46

NC

47

P6

GND 5

RXD 2

TXD 3

DB-9

CONNESSIONE

ALLA POR

TA COM

DEL PC

C

C

21

33

NO

NO

22

34

NC

NC

23

35

RELÈ 1

RELÈ 5

C

C

24

36

NO

NO

25

37

NC

NC

26

38

RELÈ 2

RELÈ 6

C

C

27

39

NO

NO

28

40

NC

NC

29

41

RELÈ 3

RELÈ 7

C

C

30

42

NO

NO

31

43

NC

NC

32

44

RELÈ 4

RELÈ 8

24

V CC

FORNITUR

A

+

24

V CC

B

A

TTERIA

+

H

N

A

C LINE

PO

TENZA

DIS

TRIB

UZIONE

+ +

+

+

+

+

+

A21

00

24

VDC –

24

VDC +

FA

UL

T

DIGITAL INPUTS

SHIELD

24

VDC +

24

VDC –

SHIELD

SHIELD

24

VDC +

24

VDC –

24

VDC +

24

VDC –

SHIELD

SHIELD

24

VDC +

24

VDC –

SHIELD

SHIELD

24

VDC +

24

VDC –

4

TO 20 MA IN

POINTW

A

TCH

C

ALIBR

A

TE

SENSOR

PO

WER

Figur

a

c

-3 -

u

n sist

ema tipico

Advertising