Filter configuration

Low crossover point

High crossover point

None

FTRL Off

FTRH Off

Highpass

FTRL not Off

FTRH Off

Lowpass

FTRL Off

FTRH not Off

Bandpass

FTRL not Off

FTRH not Off

FRQL FRQH

FRQH

FRQL

6.5

INPUT COMPRESSOR

THRESH:

The compressor threshold ranges from -20 to +20dBu in 0.5dB steps.

ATTACK:

The compressor attack time ranges from 0.3 to 1ms in 0.1ms steps, then ranges from 1 to
100ms in 1ms steps.

RELEASE:

The compressor release time can be set at 2X, 4X, 8X, 16X or 32X the attack time.

RATIO:

The compressor ratio is the slope in which the signal is compressed. It ranges from 1:1 to
1:40.

6.6

INPUT/OUTPUT CHANNEL NAME

NAME:

A 6 characters name can be assigned to each channel.

O1: ______

C omp

THRESH:+20.0dB

O1: ______

Comp

ATTACK:10ms

O1: ______

Comp

RELEASE:8X Atck

O1: ______

Comp

R ATIO : 1:1

I1: ______

Name

NAME: ______

6.7

OUTPUT LIMITER

THRESH:

The limiter threshold ranges from -20 to +20dBu in 0.5dB steps.

ATTACK:

The limiter attack time ranges from 0.3 to 1ms in 0.1ms steps, then ranges from 1 to 100ms
in 1ms steps.

RELEASE:

The limiter release time can be set at 2X, 4X, 8X, 16X or 32X the attack time.

6.8

OUTPUT SOURCE

IN1-2:

This sets the input channel source for the current output channel. It can be used to mix the
input source (in dB) or disable it (Off). If more than one input sources are enabled, they will
be added together as the source for the current output channel.

7.0

OPERATING THE SYSTEM MENUS

The System Menus allow the user to control and change parameters that are related to the
system behavior and general operation. It can be accessed by pressing the Sys key in the
main menu (when no Input/Output or System Menu is activated). All System Menus
require pressing the Enter key to confirm and save the settings.

7.1

PRESET RECALL

The DSX 2040 has a built in non-volatile memory that can store up to 30 different preset
setups.

P:

This control selects which program to recall from the non-volatile memory. The program
name is displayed to the right of the program no.

O1: ______

Source

I N 1: Off

O1: ______

Source

I N2 : - 14.00

O1: ______

Limit

THRESH:+20.0dB

O1: ______

Limit

ATTACK:10ms

O1: ______

Limit

RELEASE:8X

Atck

SYSTEM Recall

P:1 ____________