Report unit number, Assign unit number, Set number of floats – VEGA VEGABAR 82 Modbus and Levelmaster protocol - Operating Instructions Manuale d'uso

Pagina 78: Set baud rate

Advertising
background image

78

10 Appendice

VEGABAR 82 • Protocollo Modbus e LevelMaster

46294-IT

-131205

Report Unit Number

Request:

Parametro

Length

Code/Data

Report Unit Number

5 characters ASCII

U**N?

Response:

Parametro

Length

Code/Data

Report Level (and Temperature)

6 characters ASCII

UuuNnn

Assign Unit Number

Request:

Parametro

Length

Code/Data

Assign Unit Number

6 characters ASCII

UuuNnn

Response:

Parametro

Length

Code/Data

Assign Unit Number

6 characters ASCII

UuuNOK
uu = new Address

Set number of Floats

Request:

Parametro

Length

Code/Data

Set number of Floats

5 characters ASCII

UuuFn

Response:

Parametro

Length

Code/Data

Set number of Floats

6 characters ASCII

UuuFOK

Se il numero viene impostato su 0, non viene più segnalato alcun livello

Set Baud Rate

Request:

Parametro

Length

Code/Data

Set Baud Rate

8 (12) characters ASCII

UuuBbbbb[b][pds]
Bbbbb[b] = 1200, 9600 (default)
pds = parity, data length, stop bit

(optional)
parity: none = 81, even = 71 (defau-

lt), odd = 71